Abstract and Applied Analysis / 2013 / Article / Tab 4 / Research Article
Exact Analytical Solution for Suction and Injection Flow with Thermal Enhancement of Five Nanofluids over an
Isothermal Stretching Sheet with Effect of the Slip Model: A Comparative Study Table 4 Comparison between the results of
and
for Ag-water nanoparticles when Pr
and
.
Present results Noghrehabadi et al. [23 ] Present results Noghrehabadi et al. [23 ] Present results Noghrehabadi et al. [23 ] Present results Noghrehabadi et al. [23 ]
0.00 0.7807764 0.78078 1.2807764 1.28078 3.3027756 3.30278 10.099020 10.09902 0.05 0.8603080 0.86031 1.5097201 1.50972 4.2053250 4.20532 13.087484 13.08748 0.10 0.9060379 0.90604 1.6564339 1.65643 4.8141236 4.81412 15.107262 15.10726 0.15 0.9303482 0.93035 1.7395348 1.73953 5.1682565 5.16826 16.283121 16.28312 0.20 0.9392930 0.93929 1.7710695 1.77107 5.3042838 5.30428 16.734937 16.73494
0.00 0.3341463 0.33415 4.1338760 4.13375 18.877000 18.87699 62.085783 62.08581 0.05 0.3374948 0.33750 3.5686858 3.56861 16.003319 16.00329 52.565657 52.56564 0.10 0.3412474 0.34125 3.0990601 3.00902 13.637179 13.63716 44.731160 44.73115 0.15 0.3441451 0.34415 2.7036778 2.70365 11.662391 11.66238 38.194788 38.19476 0.20 0.3458192 0.34582 2.3673248 2.36732 9.995764 9.99572 32.679360 32.67934