Research Article

Estimation of Static Pull-In Instability Voltage of Geometrically Nonlinear Euler-Bernoulli Microbeam Based on Modified Couple Stress Theory by Artificial Neural Network Model

Table 1

Beam geometry and pull-in voltage for verification analysis.

Test number (μm (μm) (μm) (volt)

1750.540.50.179
21005612.44
31251081.57.31
41502010216.82
517525122.526.78
62003014340.27
722535163.553.84
82504018468.01
927545204.584.53
1030050225103.62