Research Article
Study of Ultrasound Transmission through an Immersed Glass Plate in view of Sonochemical Reactor Design Optimisation
Table 2
Main results obtained in cylindrical reactor.
| Angles | Hydrophone position | Vpp max | Transmission coefficient |
| 20° | 8 cm | 2.7 | 0.50 | 12 cm | 2.4 | 0.50 | 16 cm | 2.2 | 0.51 | 30° | 8 cm | 2.1 | 0.28 | 12 cm | 2.1 | 0.29 | 16 cm | 1.6 | 0.30 | 40° | 8 cm | 0.6 | 0.02 | 12 cm | 0.6 | 0.02 | 16 cm | 0.6 | 0.02 |
|
|