Research Article
Experimental and Numerical Evaluation of Direct Tension Test for Cylindrical Concrete Specimens
Table 3
Results for direct tension tests presenting mean/standard deviation (MPa).
| Mix | Batch | Compressive strength | Flexural tensile strength | Splitting tensile strength | Direct tensile strength |
| M-1 | B-1 | 23.4/1.26 | 3.75/0.18 | 2.28/0.15 | 1.55/0.06 | B-2 | 24.8/0.82 | 3.93/0.25 | 2.33/0.15 | 1.77/0.12 | B-3 | 23.7/0.79 | 4.48/0.23 | 1.82/0.28 | 1.52/0.04 |
| Mean/std. | 24.0/1.09 | 4.05/0.38 | 2.14/0.30 | 1.61/0.14 |
| M-2 | B-4 | 38.2/1.44 | 5.07/0.40 | 3.02/0.24 | 2.13/0.15 | B-5 | 38.2/0.35 | 5.00/0.21 | 3.01/0.16 | 2.13/0.07 | B-6 | 39.2/0.18 | 5.24/0.16 | 3.03/0.29 | 2.25/0.06 |
| Mean/std. | 38.5/0.90 | 5.10/0.26 | 3.02/0.21 | 2.17/0.11 |
| M-3 | B-7 | 54.0/1.43 | 6.07/0.34 | 3.84/0.13 | 2.44/0.11 | B-8 | 59.2/1.56 | 6.73/0.33 | 3.80/0.41 | 2.53/0.08 | B-9 | 56.7/3.65 | 6.78/0.41 | 3.84/0.20 | 2.50/0.06 |
| Mean/std. | 56.6/3.06 | 6.53/0.47 | 3.83/0.24 | 2.49/0.08 |
|
|