The maximum structural displacements for the harmonic load.

Control caseMaximum displacement (cm)
Floor 1Floor 2Floor 3Floor 4Floor 5

Control off1.2152.2883.3683.9393.912
A5-S40.4140.7691.1391.3011.305
A5,4-S40.3880.6660.9831.1611.125
A5,4,3-S40.440.8461.1371.3141.373
A5,4,3-S4,30.2840.5220.7760.961.335
A5,4,3-S4,3,50.2170.4170.5530.7560.983
A5,4,3-S4,3,5,20.1730.3220.4980.7190.989