Research Article

Accuracy Assessment of Shake Table Device on Strong Earthquake Output

Table 7

Energy-TH index of each case and frequency range of each test case.

TestSignal typeFrequency range (Hz)Energy-TH index of each case
Case 1Case 2Case 3Case 4Case 5Case 6Case 7Case 8

HSAcceleration0.1–300.1470.1680.1700.218
HP0.1–500.0240.0250.0280.0300.0370.0390.0400.045
IB0.1–500.0410.0460.0680.0760.1080.133
LS0.1–1000.0210.0720.0730.0800.0850.0910.109
CBDisplacement0.1–50.0190.0210.0270.0270.0290.0300.049