Research Article
Accuracy Assessment of Shake Table Device on Strong Earthquake Output
Table 8
Double parameter performance table for accuracy assessment of shake table devices.
| Performance index 1 | Correlation coefficient | Performance index 2 | | Level 1 (0.95 < c ≤ 1) | Level 2 (0.90 < c ≤ 0.95) | Level 3 (0.85 < c ≤ 0.90) | Level 4 (0.7 < c ≤ 0.85) | Level 5 (c ≤ 0.7) |
| Energy-TH index | Level 1 (0 < b ≤ 0.05) | HP-6, HP-7, HP-8, CB-1, CB-2, CB-3, CB-4, CB-5, CB-6, CB-7 | LS-3, HP-1, HP-2, HP-3, HP-4, HP-5 | IB-5 | IB-4 | | Level 2 (0.05 < b ≤ 0.1) | | LS-2 | LS-1, LS-4, LS-7 | LS-5, IB-1 | IB-6 | Level 3 (0.1 < b ≤ 0.15) | | | LS-6 | | IB-2, IB-3, HS-2 | Level 4 (0.15 < b ≤ 0.2) | | | | HS-1 | HS-3 | Level 5 (b > 0.2) | | | | | HS-4 |
|
|