Research Article
Intelligent Noise Removal from EMG Signal Using Focused Time-Lagged Recurrent Neural Network
Table 12
Selection of transfer function for various NN models on test
dataset.
| S.N. |
NN | Signal | Transfer function | Tanh | Linear tanh | Linear | MSE | r | MSE | r | MSE | r |
| 1 | MLP | N | 0.02501 | 0.78114 | 0.02557 | 0.77557 | 0.02521 | 0.7792 | EMG | 0.02485 | 0.58433 | 0.0251 | 0.5779 | 0.02513 | 0.5781 |
2 | FTLRNN | N | 0.00027 | 0.99797 | 0.00015 | 0.99882 | 0.000067 | 0.99843 | EMG | 0.00023 | 0.99695 | 0.00013 | 0.9981 | 0.000048 | 0.99731 |
3 | RBF | N | 0.2473 | 0.78385 | 0.02482 | 0.78297 | 0.02477 | 0.7839 | EMG | 0.02481 | 0.5852 | 0.02481 | 0.5851 | 0.02480 | 0.5854 |
|
|