Research Article

Oil and Grease Removal from Industrial Wastewater Using New Utility Approach

Table 1

Characteristic of wastewater and sludge.

ParameterUnitIndustrial wastewaterSludge

Temp. °C18.920.1
pH8.48.81
ECmmhos/cm2.343.14
TSSmg/L132345
TDSmg/L15032041
D.Omg/L3.21.35
CODmg/L5723100
BODmg/L388400
TOCmg/L60.1300
Oil and greasemg/L292.40.005
Total coliform CFU/100 mL645 × 103245 × 107