Research Article
A Soft Computing Approach to Crack Detection and Impact Source Identification with Field-Programmable Gate Array Implementation
Table 4
Labels for the input function of CDISI fuzzy inference system.
| Range | Labels | LL | LH | ML | MM | MH | HL | HH | VH |
| Arms | 0.1–1.1 | 1.1–1.4 | 1.4–1.7 | 1.7–1.9 | 1.9–2.3 | 2.3–3.5 | 3.5–4 | >4 | Amax | 0–6.5 | 6.5 | 6.5–8 | 8 | 8–10 | 10 | 10–17 | >17 | Brms | 0–1.5 | 1.5–2.4 | 2.4–2.9 | 2.9 | 2.9–3.3 | 3.3 | 3.3–4.0 | >4 | Bmax | 0–10 | 10 | 10–13 | 13 | 13–15.4 | 15.4 | 15.4–17 | >17 | Frequency (KHz) | 1–30 | 30–60 | 60–70 | 70–80 | 80–90 | 90–100 | 100–110 | >110 | Avg. RMS voltage | 0–0.001 | 0.001–0.00199 | 0.00199–0.00225 | 0.00225–0.00250 | 0.00250– 0.002971 | 0.002971–0.003111 | 0.003111–0.004 | >0.004 | Standard deviation | ≤0.00003 | 0.00003–0.00003229 | 0.00003229–0.00006229 | 0.00006229–0.0001 | 0.0001–0.0001889 | 0.0001889–0.000199 | 0.000199–0.00021 | >0.00021 |
|
|