Research Article

Innovative Strategy to Improve Precision and to Save Power of a Real-Time Control Process Using an Online Adaptive Fuzzy Logic Controller

Table 6

Comparative performance indices before and after the perturbation.

MSE in 10 minutes +25% in the power of 
the fan
−20% in the power of 
the fan
FLCAdaptive
FLC
FLCAdaptive
FLC

Before
perturbation
0.780.420.640.1
After
perturbation
0.320.361.770.14