Research Article
Performance of Sprayed Fiber Reinforced Polymer Strengthened Timber Beams
Table 3
Summary of results: creosoted.
| | Ultimate load (kN) | Ultimate displacement (mm) | Energy absorbed (kJ) | Load % increase over F | Energy absorbed % increase over F | FRP rupture |