Research Article

Effects of Aging Temperature on Moisture Absorption of Perforated GFRP

Table 2

Bending test results for specimens aged at various temperatures (humidity 60%).

Specimen/conditionFailure force (N)*Maximum displacement (mm)Stiffness, K (N/mm)*Standard deviation

R-01/original176.052.282.50.104
H 4/T = 40°C153.161.980.30.102
H 6/T = 60°C139.081.878.20.104
H 8/T = 80°C123.241.676.60.106

The reported data are the mean values of 3 results for each category.