Research Article

Experimental Research on Fire Resistance of Reactive Powder Concrete

Table 1

Mix proportions and compressive strength of RPC tested.

No.Type of RPCW/BQuantity (kg/m3)28d strength (MPa)
CementWaterSandSilica fumeSteel fiberPP fiber

(1)0.16S2.00.1672014411661801560105.3
(2)0.18S2.00.187201621080180156080.8
(3)0.18P0.10S2.00.1872016210801801560.9190.2
(4)0.18P0.15S2.00.1872016210801801561.3795.6
(5)0.18P0.20S2.00.1872016210801801561.8280.9
(6)0.20S2.00.207201801166180156086.3
(7)0.16P0.15S2.00.1672014411661801561.3797.9
(8)0.20P0.15S2.00.2072018011661801561.3770.2