Research Article
Fracture Energy Estimation of DCB Specimens Made of Glass/Epoxy: An Experimental Study
Table 1
Critical load,
, and corresponding displacement,
δ cr, for the measured crack length of a DCB specimen made of unidirectional glass/epoxy composite.
| Test results | Present analysis | Crack length, (mm) | (N) | δ (mm) | (N) (12) | δ
cr (mm) (8) | % Relative error in | , (18) | Load | Displacement |
| 44 | 127.77 | 6.22 | 138.15 | 6.47 | −8.13 | −4.11 | 161.77 | 45 | 125.89 | 6.33 | 135.49 | 6.74 | −7.63 | −6.37 | 158.18 | 46 | 125.41 | 6.68 | 132.93 | 7.01 | −6.00 | −4.88 | 154.74 | 47 | 123.16 | 6.94 | 130.46 | 7.28 | −5.93 | −4.92 | 151.45 | 48 | 121.15 | 7.21 | 128.09 | 7.56 | −5.73 | −4.83 | 148.29 | 53 | 118.99 | 9.19 | 117.42 | 9.03 | 1.32 | 1.69 | 134.30 | 58 | 117.13 | 11.48 | 108.41 | 10.63 | 7.45 | 7.40 | 122.72 | 63 | 108.78 | 13.29 | 100.68 | 12.36 | 7.45 | 7.05 | 112.98 | 68 | 104.84 | 15.73 | 93.99 | 14.21 | 10.34 | 9.66 | 104.68 |
|
|
Layup: , mm, mm, mm, GPa, Nm, and J/m2.
|