Comparison of energy release rate and Young’s modulus of unidirectional composites based on analytical data reduction schemes.

MaterialCritical energy release rate, (J/m2)Young’s modulus, (GPa)
Strength of material approach (11)Cubic lawPower lawPublished resultCubic lawPower law

Carbon/PEEK [1]2006.372051.682149.03130.0129.94136.06
Carbon/epoxy [1]262.73261.60287.90136.0135.60139.65
Carbon/PES [17]2150.642121.762230.22127.0126.43131.15
T300-634 DDS [19]642.13641.01641.80133.0132.53133.06
Carbon/epoxy [20]364.07361.60428.94150.0135.99137.41
CYCOM-982 [21]262.33264.10271.79136.0137.65141.87
APC-2 [21]1563.811582.461655.85129.0130.75133.56
Carbon/PEK-C [16]877.33873.70875.1248.246.8049.94
Carbon/BMI T300/QY8911 [18]170.60196.09214.54135.0133.46141.12
Glass/BMI S2/QY8911 [18]1090.401098.871217.0742.843.254.09
Glass/epoxy [14]1175.53806.60854.5048.540.3558.01
Glass/Polyester [22]1018.161018.111203.3533.039.4841.15
Glass/epoxy, Present test1075.001109.511098.4836.033.538.6