Research Article

Reduction of Postfire Properties of High-Strength Concrete

Table 2

Hot compressive strength of concrete specimens while heated to a predetermined temperature level—(a).

PropertyTemperature level (°C)
20200400500600

(MPa)63.665.851.538.727.7
61.8Mean
62.2
58.8Mean
62.2
47.0Mean
50.0
39.9Mean
39.9
32.3
61.361.951.441.126.9