Research Article

New Measurement Method and Uncertainty Estimation for Plate Dimensions and Surface Quality

Table 4

The classification results of tile third specimen.
(a)

Test no.Measured values
, mm , mm , mm

10.66080.57230.0031
20.65110.56080.0220
30.65220.56000.0225
40.65290.56060.0213
50.65290.56050.0218

Average0.65400.56280.0181
Maximum0.66080.57230.0225

(b)

Specific calculated parameters, %

0.110.110.04