Research Article

New Measurement Method and Uncertainty Estimation for Plate Dimensions and Surface Quality

Table 8

The classification results of tile second sample using new measurement method in mm.
(a)

Test no.Measured values of Measured values of Measured values of
at at at at at at

10.78140.83750.67730.96250.14530.2481
20.78120.83770.67670.96250.14510.2478
30.78120.83770.67710.96260.14540.2480
40.78080.83770.67720.96230.14530.2478
50.78050.83740.67680.96250.14530.2477

Average0.78100.83760.67700.96250.14530.2479
Maximum 0.83770.96260.2481

(b)

Specific calculated parameters, %

0.140.180.04