Research Article

Safety Analysis in Large Volume Vacuum Systems Like Tokamak: Experiments and Numerical Simulation to Analyze Vacuum Ruptures Consequences

Table 1

Flow rate setting.

TemperaturePressurization rateFlow rate

120–130°C100 Pa/s10 lt/min
300 Pa/s26.5 lt/min
500 Pa/s52 lt/min