Research Article

Influence of Humidity on Fiber Bragg Grating Sensors

Table 2

Bragg wavelength shifts and equivalent temperature variation obtained at different measurement conditions for each FBG sensor.

(°C)FBG_1FBG_2FBG_TEMP

70 (nm)1552.4951573.5621525.716
(nm)1552.5671573.4771525.698
(nm)0.072−0.085−0.018
(°C)3.033.740.72

60 (nm)1552.3741573.3191525.438
(nm)1552.4601573.2191525.420
(nm)0.087−0.100−0.018
(°C)3.634.450.69

50 (nm)1552.2801573.0491525.161
(nm)1552.3531572.9741525.150
(nm)0.051−0.055−0.010
(°C)2.122.850.40

40 (nm)1552.1731572.8061524.888
(nm)1552.2571572.7201524.881
(nm)0.053−0.047−0.005
(°C)2.212.080.20

30 (nm)1552.0641572.5721524.623
(nm)1552.1521572.4751524.614
(nm)0.089−0.097−0.008
(°C)3.714.290.34

22 (nm)1551.9851572.3771524.415
(nm)1552.0761572.2851524.407
(nm)0.091−0.092−0.008
(°C)3.834.060.30

10 (nm)1551.8981572.0651524.102
(nm)1551.9531572.0081524.092
(nm)0.055−0.058−0.010
(°C)2.292.550.40