Research Article

Parallel Piezoelectric Shunt Damping of Rotationally Periodic Structures

Figure 9

Simulation response of one blade with independent RL loops. (a) Normalized FRF between the forcing function and the velocity measured at the blade tip, (b) cumulative RMS of .