Research Article

Soft Sensor for Oxide Scales on the Steam Side of Superheater Tubes under Uneven Circumferential Load

Table 6

The maximum forecasting errors for the stress.

90°180°

Axial stress maximum error/[MPa]76.8540.9924.28
Circumferential stress maximum error/[MPa]58.3843.4541.32
Radial stress maximum error/[MPa]4.394.461.99