Abstract

The effects of the addition of different nanosilica dosages (0.5%, 1%, and 1.5% with respect to cement) on compressive strength and durability properties of concrete with water/binder ratios 0.65, 0.55, and 0.5 were investigated. Water sorptivity, apparent chloride diffusion coefficient, electrical resistivity, and carbonation coefficient of concrete were measured. The results showed that compressive strength significantly improved in case of water/binder = 0.65, while for water/binder = 0.5 no change was found. Increasing nanosilica content, the water sorptivity decreased only for water/binder = 0.55. The addition of 0.5% nanosilica decreased the apparent chloride diffusion coefficient for water/binder = 0.65 and 0.55; however, higher nanosilica dosages did not decrease it with respect to reference value. The resistivity was elevated by 0.5% nanosilica for all water/binder ratios and by 1.5% nanosilica only for water/binder = 0.5. The carbonation coefficient was not notably affected by increasing nanosilica dosages and even adverse effect was observed for water/binder = 0.65. Further information of microstructure was also provided through characterization techniques such as X-ray diffraction, thermal gravimetric analysis, mercury intrusion porosimetry, and scanning electron microscopy. The effectiveness of a certain nanosilica dosage addition into lower strength mixes was more noticeable, while, for the higher strength mix, the effectiveness was less.

1. Introduction

In recent years, modification of cement composites by nanoparticles has attracted intense attention among researchers. Concrete, as the most popular cement composite in practical applications, was also subjected to modification by replacing a portion of binder with various nanoparticles such as TiO2 [1], Fe2O3 [2], Al2O3 [3], and SiO2. Among those, nanosilica (NS) incorporation into concrete was of interest for many researchers not only because of the similarity of its chemical composition to constituents of C-S-H, but also because of the capability of NS to potentially improve cement composites properties through different mechanisms. NS, as well as silica fume [4], is a highly reactive pozzolan and could consume calcium hydroxide (CH) to form secondary C-S-H [5, 6]. However, some researchers [7] believe that the addition of NS mostly affects initial silicate polymerization rather than ultimate amount of C-S-H formed. Another mechanism, by which NS can influence cement composite properties, is seeding effect. NS could provide extra sites for the precipitation of hydration products, leading to the acceleration of early stage hydration [5].

The modification of macroscopic properties of concrete by NS addition has been subjected to intensive study. As far as compressive strength is concerned, controversial results were obtained sorting enhancements from notable [8, 9] to moderate [1014], even though no gains were reported [15, 16]. A certain NS content produced different effects on the strength when NS was incorporated into concrete with different water/cement (w/c) ratios. For instance, employing a content of NS around 1% NS into concrete with w/c ratio of 0.4 [3] and 0.48 [12] resulted in quite different gains in compressive strength of about 20% and 12%, respectively. Similarly, utilization of 2% NS in high volume binary blended concrete with water to binder (w/b) ratio of 0.4 [17] and 0.45 [14] produced null and 16% strength gain, respectively. Moreover, when such a small content (i.e., 1-2%) of NS was added, no analogous trend in strength improvement was seen by increasing w/c ratio of concrete of former case from 0.4 to 0.48 (descending trend) and those of latter case from 0.4 to 0.45 (ascending trend). It should be underlined that this discrepancy may have arisen due to the essence of utilized NS in each study such as production method, particle size, agglomeration state (specific surface area), and above all agglomeration state after coming into contact with cement in aqueous media. Even subsequent timing of superplasticizer addition to the mixture plays a role in the effectiveness of NS incorporation on properties of concrete [18].

Concrete is normally reinforced by steel rebars. Besides compressive strength, durability properties are also of high importance, when dealing with reinforced concrete. While strength of concrete containing NS has received particular attention in the last decade, less consideration has been paid to its durability properties. So, recently, there are increasing number of studies in which several durability related properties of cement composites were investigated such as water sorptivity [9, 12, 1922], resistance to chloride penetration [12, 13, 2124], electrical resistivity [2225], and carbonation resistance [26, 27].

Jalal et al. [9] found that the water absorption of concrete decreases with the addition of NS. Similar findings were, also, reported by Supit and Shaikh [19] for water sorptivity of concrete. In another study, Du et al. [12] reported that water absorption and water sorptivity of concrete were not influenced by NS. Quercia et al. [13] obtained that NS addition slightly increased the air content of fresh state concrete. The water absorption of mortar with was reduced by the addition of 2.5% NS [21], while a little higher content of NS (around 3%) increased the water absorption of mortar with [26]. As for compressive strength, the same NS addition into mortars with different w/c ratios did not produce corresponding effects. Du et al. [12] and Quercia et al. [13] reported that chloride diffusion coefficient of concrete was reduced by NS addition. According to Madani et al. [24] and Belkowitz et al. [25], the bulk electrical resistivity of concrete samples was increased after the addition of NS.

As far as carbonation resistance is concerned, Rao et al. [26] reported no change in carbonation resistance of mortar containing NS, while Lim and Mondal [27] found that 5% NS addition to cement paste led to reduction in the degree of carbonation. Although there are some works considering carbonation resistance of cementitious materials, detailed quantitative data on NS impact on the advancement of carbonation in time, especially in concrete, are lacking in the literature.

The impact of NS on the durability properties of concrete, particularly when considering various w/c ratios, is not fully understood. The main goal of this study is to investigate NS effects on the durability properties of concrete such as water sorptivity, resistance to chloride penetration, electrical resistivity, and carbonation resistance. Microstructure characterization techniques such as X-ray diffraction, thermal analysis, mercury intrusion porosimetry, and environmental scanning electron microscopy were employed to achieve better understanding of how NS influences the factors by which those durability properties are controlled such as CH content and porosity distribution.

2. Materials and Experimental Methodology

2.1. Materials

Concrete was cast with CEM I 42.5R; crushed limestone aggregates, divided in five different classes (sand and calc1–calc4), with maximum size of 12.5 mm were used; the combination was chosen in order to fit Fuller’s grading curve (Figure 1). Saturated surface dried (SSD) density, absorption (%) and fraction combination of five classes of aggregates are summarized in Table 1. Commercial NS suspension with the concentration of 10% by weight of water with nominal mean particle size of 20 nm was used. SEM image of dried NS (Figure 2) shows particle size lower than 100 nm, which could be the agglomeration of 3-4 nanoparticles and it probably was caused by drying process for SEM observation. Particles size distribution and cumulative distribution, conducted by measurement technique of dynamic light scattering (DLS), showed that 51% of the volume of suspension had particle size finer than 21 nm and the most probable particle size belongs to 18 nm, that is, 25% of the suspension volume (Figure 3). Furthermore, only 5% volume fraction of the tested suspension had the size higher than 100 nm. Thus, NS suspension was well dispersed in water with little degree of agglomeration; however, this did not guarantee uniform dispersion of NS after mixing with solids inside concrete.

2.2. Samples Preparation

Concrete samples with w/b ratios of 0.65, 0.55, and 0.5 were cast. The composition of each concrete is shown in Table 2. The mix was designed so that all concrete samples had the same volume of cement paste. For each w/b ratio, three NS contents of 0.5, 1, and 1.5% with respect to cement mass were considered as replacement of cement. NS suspension was added to the mixing water taking into account water content of suspension and it was stirred manually; then superplasticizer (SP) was added to the water mixture. Cement and aggregates were mixed and then water containing NS and SP was added. For each type of concrete, 4 cubes  mm were cast for compressive strength; a slab with  mm dimension was also cast. Cylindrical samples with nominal 100 mm diameter were cored from the slab at the age of 28 days of curing. The surface in contact with mould (mould surface) was ground, while the casting surface (trowelled surface) remained unchanged. All tests were performed on replicate specimens except chloride diffusion test.

2.3. Test Methods
2.3.1. Compressive Strength

The compressive strength test was performed according to EN-12390-3 on cubes moist-cured in curing chamber for 7 and 28 days.

2.3.2. Sorptivity and Water Absorption

Capillary water absorption was measured as the mass of liquid absorbed per unit surface (, kg/m2) of cylindrical specimens in time . The specimens were oven-dried for 1 week at 40°C to obtain dry mass and thereafter the mould surface was put in contact with demineralized water. Water sorptivity (, kg/m2 h0.5) was calculated using values at 24 h according toThen, the specimens were immersed in demineralized water until constant mass for calculating total water absorption (%) as the difference between saturated mass and dry mass with respect to dry mass.

2.3.3. Chloride Penetration Resistance

Chloride penetration test was carried out according to CEN/TS 12390-11 [28]. The specimens were placed in vacuum container with absolute pressure of 1–5 kPa for 3 h. The container was filled with demineralized water for 1 h with the pump still running. Soon after, the samples were placed in the lab for 2–4 h in order for their surface to become dry. All the surfaces but one (mould surface) were covered with epoxy resin and immersed in saturated calcium hydroxide for 18 h and were finally immersed in sodium chloride solution with concentration of 3% by mass of solution for 90 days. At the end of the exposure, the specimens were ground to collect powder samples at different depths for acid soluble chloride analysis according to EN 14629 [29]. Chloride content (%) of each layer was obtained and apparent chloride diffusion coefficient and surface chloride content were obtained through the interpolation of the chloride profile according to EN 14629 [29].

2.3.4. Electrical Resistivity

The electrical resistivity test was done by measuring conductance, , across cylindrical specimens. The mould surface of the samples was not ground for this test. The samples were immersed immediately after coring in demineralized water and kept at 20–25°C temperature; periodically, for approximately 4 months, the conductance was recorded. The conductance was then converted to electrical resistivity, , in Ωm using the geometry of the samples:where and are surface area and height of the samples.

2.3.5. Carbonation Resistance

Cylindrical specimens were conditioned inside the lab for 14 days with 18–25°C temperature and 50–65% relative humidity and the side surface of the specimens was then covered with epoxy resin. The specimens were placed inside an accelerated carbonation chamber with 4% CO2 concentration, % relative humidity, and 20°C temperature. The depth of carbonation was measured (by 0.5 mm accuracy) after 45 and 135 days by phenolphthalein indicator. For each surface (trowelled or mould), the reported carbonation depth value was an average of 10 points. The data was interpolated with (3) and carbonation coefficient (mm/√year) was determined (for unidirectional diffusion):where is the depth of carbonation in mm and is the time in year.

2.3.6. Microstructural Characterization

CH content of concrete samples was estimated by X-ray diffraction (XRD), thermal gravimetric analysis, and differential thermal analysis (TGA/DTA).

Diffracted X-ray patterns were acquired in a range of 2θ from 15 to 60 degrees with radiation of Cu(Kα) tube (40 kV and 40 mA) with  Å, step size of 0.02 degrees, and scan rate of 0.2 deg/s. The Jade software suite version 6 was used to characterize the mineralogical crystalline phases.

TGA/DTA tests were performed using isothermal analyzer on ground fragments of concrete, approximately 100 mg. This test was performed under a nitrogen flow of 50 mL/min. The temperature was programmed rising from ambient temperature of 25°C by the rate of 10°C/min up to 900°C and temperature was held at 105°C for 2 hours to promote evaporation of free water. The amounts of CH were estimated as where CH is the calcium hydroxide weight percentage, corresponds to the percent weight loss associated with CH decomposition, and and are the molecular weight of CH (74.01 g/mol) and water (18 g/mol), respectively.

Porosity analysis was conducted by mercury intrusion porosimetry (MIP) and morphology was observed by environmental scanning electron microscopy (ESEM) on concrete fragments collected from broken samples of compressive strength test at 28 days. The samples for MIP, XRD, thermal analysis, and ESEM were selected according to the best performance of compressive strength of concrete incorporating NS compared with the references.

3. Results

3.1. Slump and Compressive Strength

The values of slump of fresh concrete are listed in Table 2. Addition of 1.5% NS significantly decreased the slump from 175 to 240 mm as reference slumps of concrete with and 0.55 to 30 and 40 mm, respectively. According to Yu et al. [11] this behavior could be explained by the formation of the sort of structure that has high water retention after the addition of NS. Consequently, the amount of lubricating water in the mixture was reduced; thus, viscosity of fresh concrete may increase and slump may decrease. The significant reduction of slump of the concrete incorporating NS could introduce more entrapped air. The slump values for did not decrease with respect to reference by increasing NS dosage, since higher amount of SP was used in order to have better workability during casting.

Figure 4 shows compressive strength of concrete after 7 and 28 days of curing as a function of NS content. The 28-days compressive strength of concrete with improved considerably by NS addition and showed progressive increase from control value of 33.8 to 47.8 MPa for 1.5% NS addition. The compressive strength after 7 days also exhibited progressive improvement from reference value of 30.3 to 39.5 MPa for 1.5% NS addition. For , the 28-day strength was elevated moderately from control 49.1 MPa to 53.8 MPa with the addition of 1% NS. The strength at 7 days also showed similar trend as 28 days and increased from 41.3 to 45.7 MPa with 1% NS. No change was observed in the strength of 28 days of concrete with , while 7-day strength rised from 47.7 to 51.5 MPa with 1.5% NS.

3.2. Water Sorptivity

Capillary water sorptivity defines the tendency of the concrete to absorb water through capillary suction by which ingress of aggressive substances can occur. As an example, typical curves of water uptake per unit surface, , as a function of square root of time, are shown in Figure 5(a) for reference and 1.5% NS addition into concrete with . The figure shows small variations of for two replicates for each concrete type. The water uptakes after 24 h were 1.91 and 2.02 kg/m2 for control and 1.5% NS, respectively. From the data of water uptake in time intervals, the average values of water sorptivity coefficient, , kg/m2 h0.5 with their variations, were calculated and shown in Figure 5(b) as a function of NS content. For , 0.5% NS addition slightly decreased the water sorptivity from reference 0.4 to 0.3 kg/m2 h0.5 and then the sorptivity reached again around reference value by higher dosages. For , it exhibited a clear reduction varying in the range between reference values of 0.34 and 0.2 kg/m2 h0.5 by NS incorporation; for , it showed slight variation between control values of 0.27 and 0.31 kg/m2 h0.5 after NS incorporation.

Figure 5(c) shows the average values of water absorption of concrete as a function of NS content. For , the addition of 0.5% NS slightly decreased the water absorption from reference value of 3.9% to 3.6%. For , it was clearly reduced from the reference value of 3.8% to 2.3% by 1% NS; for , it exhibited a slight variation between values 2.7% and 3.1% after NS incorporation.

3.3. Chloride Penetration Resistance

Chloride penetration test was conducted to investigate the resistance of concrete against ingress of chloride ion during a nonstationary diffusion process. As an example, typical chloride content profiles for and 1.5% NS in comparison with reference are shown in Figure 6(a). From chloride profile interpolation, the apparent chloride diffusion coefficient, , and surface chloride content, , of each concrete were calculated and presented in Figures 6(b) and 6(c), respectively. For , the diffusion coefficient slightly decreased from reference value of 19.1 to 15.2 × 10−12 m2/s for 0.5% NS and unexpectedly increased to 32 × 10−12 m2/s for 1% NS; then it decreased to 18.9 × 10−12 m2/s for 1.5% NS, close to the reference value. For , clearly decreased from control value of 18.1 to 10.4 × 10−12 m2/s for 0.5% NS and it reached around the reference value with the addition of higher dosages; for , initially increased for 1% NS addition and then it decreased with respect to reference after the addition of 1.5% NS. The surface chloride content, , exhibited small variations. For , 0.55, and 0.5, the variation range was 0.21–0.26%, 0.32–0.35%, and 0.28–0.42% of mass of concrete, respectively.

3.4. Electrical Resistivity

Electrical resistivity of concrete may be useful for the monitoring and inspection of reinforced concrete structures with regard to reinforcement corrosion [30] and is a measure of ion permeability of concrete in saturated condition. A denser concrete results in lower permeability and consequently higher electrical resistivity. Immersing concrete samples in water after 28 days of moist curing, hydration of the cement grains continued and porosity and pore connectivity reduced; consequently, the electrical resistivity increased progressively through the time. The electrical resistivity of concrete with for reference and with 1.5% NS, as an example, as a function of time of immersion for two replicates of each type, is shown in Figure 7(a); zero time is the day of immersion. The average electrical resistivity curves experienced a sudden drop after immersion due to saturation with water and the resistivity after the drop is labeled as . Then, the resistivity increased and the average value after 85 days (labeled as ; see Figure 7(a)) was reported as an indication of the resistivity when hydration degree of cement is close to ultimate. Variations of these two parameters as a function of NS content for all concrete are shown in Figure 7(b). An addition of 0.5% of NS led to increase with respect to reference from 53 to 61 Ωm, from 57 to 67 Ωm, and from 69 to 77 Ωm for concrete with , 0.55, and 0.5, respectively; thereafter, by increasing NS dosage, the resistivity of and 0.55 did not considerably change as compared to reference. Comparing the resistivity of concrete with to those of 0.65 and 0.55, a different behavior was observed. The highest reading of was 87 Ωm for 1.5% NS with . The value of is an indication of permeability of each concrete when hydration degree of cement grains in the concrete is close to ultimate and showed approximately similar trend with that of by increasing NS content.

3.5. Carbonation Resistance

A typical curve of carbonation depth versus time of exposure is presented in Figure 8(a) for trowelled surface of and 1.5% NS in comparison with reference. The carbonation depth increased from 14.1 mm for reference to 17.5 mm for 1.5% NS after 135 days of exposure. Carbonation coefficient, , is known as a slope of the interpolated line in the figure and is depicted in Figures 8(b) and 8(c) as a function of NS content for trowelled and mould surfaces, respectively. For and trowelled surface, increased from control of 24 to a maximum of 29.3 mm/√year for 1% NS addition, while, for , was reduced from 20.8 to a minimum of 16 mm/√year for 1% NS. For , no significant changes for values were observed. Comparing Figures 8(b) with 8(c), the values for trowelled surface were slightly higher than those of mould surface, probably because trowelled surface was affected by bleeding. It is known that the carbonation resistance depends on various factors such as CH content and porosity of concrete. For this sake, CH contents of each concrete type were evaluated qualitatively by XRD analysis and more quantitatively by thermal analysis in order to describe the carbonation results.

3.6. Microstructural Characterization
3.6.1. X-Ray Diffraction

Figure 9 shows XRD pattern of selected concrete samples represented by intensity counts/s versus diffraction angle (). Intense peaks of dolomite (CaMg(CO3)2) and calcite (CaCO3) coming from calcareous aggregates are visible in the figure. Intensity counts of peaks of are associated with the main peak of CH crystals. Comparing the intensity of this peak of control with NS containing concrete, it was found that CH content only decreased in concrete with after NS addition. This result was further investigated with thermal analysis.

3.6.2. Thermal Analysis

Figure 10 shows as an example the TGA/DTA graphs for concrete with and 1.5% NS in comparison with control. The CH weight loss (in range of 420–510°C) and dolomite and calcium carbonate weight losses (720–810°C and 820–890°C, resp.) are shown using DTA peaks. The calculated CH contents using (4) are listed in Table 3. The CH content of concrete with sharply decreased from reference value of 5.06% to 2.71% by weight. In contrast, CH content for other concrete types practically exhibited no change by NS incorporation. This outcome is in accordance with the findings of XRD analysis.

3.6.3. Porosity and Pore Size Distribution

Figures 11(a), 11(b), and 11(c) report differential pore distribution (), that is, the relationship between pore volume, , and pore size, , in the range of 6 nm to few hundreds μm for different specimens. The higher is the value of , the higher is the pore volume fraction related to a certain pore size with respect to total porosity volume. Cumulative intrusion volume (mL/g) is depicted in Figures 11(d), 11(e), and 11(f). Pores in the range ≤10 nm, 10–50 nm, and 50–10000 nm are classified according to [31] as gel pores, micropores, and macropores, respectively, and porosity percentage of each category is also shown in Figures 11(d), 11(e), and 11(f). Gel pores do not contribute to strength and permeability, unlike the micro- and macropores that influence strength and durability properties. Total intrusion volume, total porosity (%), and median pore size (nm) are presented in Table 4.

Figures 11(a) and 11(d) show that macroporosity for and total porosity (Table 4) did not change by 1.5% NS addition with respect to reference; limited refinement was observed in microporosity by NS addition. The gel porosity was elevated considerably by 1.5% NS addition with respect to reference. This could be an indication of higher C-S-H gel formed when NS was incorporated [13, 14]. From Figures 11(b) and 11(e), for , the micro- and macroporosity and the total porosity (Table 4) were clearly reduced with respect to control. The gel porosity increased moderately but not as much as that of . Finally, for , Figures 11(c) and 11(f) reveal that microporosity did not change after 1.5% NS addition, while macroporosity showed slight reduction with respect to control. Table 4 shows that the total porosity moderately decreased with respect to reference and the reduction was smaller than that of . The gel porosity was raised by 1.5% NS but, in comparison with the other two w/b ratios, was of minor concern.

3.6.4. Morphology Observation

Micrographs of concrete, as an example, for reference and 1.5% NS with , are depicted in Figure 12. Large plates of CH and ettringite needles are clearly visible in Figure 12(a) as shown with solid and hollow arrows, respectively. As expected, no sign of partially reacted NS was seen in Figure 12(b) in contrast to [18] who claimed the observation of unreacted NS agglomeration after 28 days of curing. It seems that NS was fully reacted and NS was no longer visible. The morphology of concrete with NS, Figure 12(b), exhibited a rather granular surface compared with plain concrete; this could be due to C-S-H precipitates around NS. Furthermore, the concrete containing NS showed more uniform morphology having less visible macropores with respect to reference, as indicated in the figure by white arrows.

4. Discussion

In order to evaluate the effects of partial replacement of cement with NS on macroscopic properties of concrete with various w/b ratios, initially the relation between the compressive strength and NS content for a specific w/b ratio is considered. Then, the effect of a certain NS content on compressive strength of concrete fabricated with different w/b ratios is explored. Similarly, for durability properties, the role of different NS dosages in a specific w/b ratio is described. Finally, the effect of a certain NS content on the properties of concrete with various w/b ratios is investigated.

The results presented in Section 3.1 reflect beneficial effect of NS on 7-day strength of concrete; see Figure 4. For each w/b ratio, increasing NS content mostly increased the strength of 7 days with respect to reference. This beneficial effect could be attributed to the accelerating effect of NS on early cement hydration. The strength of 28 days exhibited slightly different behavior, increasing NS dosage. It showed generally ascending trend as a function of NS content for ; it increased with a gentle slope and reached a maximum after 1% NS addition for . For , Figure 4(c) shows that the strength did not vary with increasing NS dosage.

For investigating the effect of a certain NS dosage on compressive strength of concrete with various w/b ratios, the strength of 7 and 28 days of concrete is depicted as a function of w/b ratio in Figure 13. For each NS dosage, the experimental data are fitted through an exponential relationship according to Abram’s law [32]. Each line is illustrative of a certain NS dosage and represents a specific exponential relationship between the strength and w/b ratio. According to Figure 13(a), for 7-day strength, the fitted lines have converging tendency towards reference (black line) by reducing w/b ratio. Decreasing w/b ratio, distance between each line and reference line decreased; thus, the strength enhancement decreased as well. Accordingly, for , the strength enhancement was larger than that of and 0.5. For 28-day strength in Figure 13(b), converging the tendency of the lines is even more pronounced than 7-day strength when w/b decreases. Considerable enhancement relative to reference was detected for . For , the enhancement was smaller than . Finally, for , no enhancement was found after the addition of NS and the lines approximately approached the reference line. The effect of a certain NS dosage was more pronounced at the lower strength mixes (higher w/b ratio). For the higher strength mix (lower w/b ratio), the effect was less. The reason probably relates to the reduction of distance between cement grains, when w/b ratio is reduced. Decreasing the distance, packing, and accelerating effects of NS may differ.

Among 28-day strength enhancements obtained above for concrete containing NS, remarkable enhancement of 41% with respect to reference was obtained for and 1.5% NS addition. This enhancement could be related to higher amount of C-S-H formed as a consequence of NS addition, as indicated by the porosity analysis (Figure 11(d)). In addition, NS led to more uniform morphology than reference concrete as evidenced by ESEM micrographs. The notable improvement in the strength could be an intriguing outcome for sustainable concrete technology, even though such a high w/b ratio is not commonly employed in practical applications. The 28-day strength was elevated to 47.8 MPa, which is close to that of reference concrete with (i.e., 49.2 MPa). This means that the same strength can be obtained by increasing w/b ratio from 0.55 to 0.65 and by the addition of NS (4.6 kg/m3; see Table 2), reducing cement content of 36 kg/m3.

The results presented in Section 3.2 reveal that no clear effect of NS incorporation into concrete on water sorptivity for and 0.5 was detected. In contrast, for , by increasing NS dosage, the sorptivity clearly decreased to a minimum after 1% NS. For resistance to chloride penetration, no comprehensible trend as a function of NS dosage was observed for concrete with various w/b ratios. For electrical resistivity, a similar trend as a function of NS dosage was detected for and 0.55. A comparative increase was observed when 0.5% NS was added; thereafter, with the increasing NS content, the resistivity decreased. Trend of variation of carbonation coefficient with the increase of NS content for , 0.55, and 0.5 was ascendant, descendent, and horizontal, respectively.

In order to investigate the relationship between w/b ratio and the effectiveness of a certain NS dosage on durability properties, measured parameters such as sorptivity (), chloride diffusion (), electrical resistivity (), and carbonation coefficient of trowelled surface () of concrete with different w/b ratios but containing a certain NS dosage are compared. Relative values (%) of a generic parameter for concrete with , 0.55, and 0.5 are shown in Figures 14(a), 14(b), and 14(c) for 0.5%, 1%, and 1.5% of NS, respectively. For a generic property, the relative value is defined as the ratio between the generic parameter for samples containing NS and that of the corresponding control with similar w/b ratio and curing time, multiplied by 100. A value above 100% shows an increase in the considered property, whilst a value below 100% shows a decrease.

As far as sorptivity of concrete is concerned, a certain NS addition into concrete with different w/b ratios did not produce clear effect. Comparing Figures 14(a) with 14(b) and 14(c), an addition of 0.5% NS into concrete with and 0.55 led to slight decrease in water sorptivity with respect to reference and for led to slight increase; however, this tendency was not maintained when higher dosages were incorporated. An addition of 1% and 1.5% NS led to no appreciable change in the sorptivity of and 0.5 with respect to reference; on the contrary, the same contents of NS led to a reduction in the sorptivity of concrete with .

As far as chloride penetration resistance is concerned, a certain NS dosage showed different effects on the chloride diffusion coefficient of concrete with different w/b ratios. Comparing Figures 14(a) with 14(c), 0.5% NS seems to be effective to promote concrete resistance to chloride penetration for and 0.55; 1.5% NS reduced the chloride diffusion coefficient of and 0.55. Thus, the tendency of reduction as a function of w/b ratio in Figure 14(a) was not maintained in Figure 14(c). Different factors are mentioned in the literature as an explanation for reducing chloride diffusivity by NS. For instance, for and 1.5% NS addition, the reduction of median pore diameter was probably enough to slightly reduce the diffusion coefficient (see Table 4) [13].

Comparing the electrical resistivity in Figure 14(a) with that in Figure 14(c), an addition of 0.5% NS increased the resistivity of concrete with all w/b ratios, while the addition of 1.5% NS only elevated that of concrete with . The chloride diffusivity and the electrical resistivity are both dependent on permeability of ions inside pore solution. As a consequence, the apparent chloride diffusion coefficient has linear correlation with inverse of the resistivity [33] and this correlation was obtained and shown in Figure 15 with a linear regression as specified in the figure. According to Figure 15, a decrease in the diffusion coefficient corresponds to an increase in electrical resistivity with a good linear proportionality. The grey data point is not included in the linear regression and this deviation from the linearity represents clearly the unexpected variation of the chloride diffusion coefficient of this data point as compared to other data; see Section 3.3. The -squared of linear regression is approximately 93% and it means that linear model could explain appropriately the variability of the data around the model.

According to Figures 14(a) and 14(b), NS was not effective to increase carbonation resistance of concrete with and 0.5 (0.5% and 1% NS), while incorporation of the similar dosages in concrete with caused relative reduction in carbonation coefficient. NS addition had negative effect on resistance to carbonation of concrete with . Regarding the fact of no variation in porosity and CH content of with 1.5% NS with respect to control, probably the reason could be that C-S-H became more impervious to neutralization and the carbonation front went faster than reference. Not only CH can be neutralized in carbonation reaction, but also carbonation of C-S-H is possible when CH is depleted. NS modifies the internal structure of the C-S-H gel stabilizing calcium ions [34].

According to the discussion above, possible beneficial effects of NS addition on the durability properties of concrete should not be inferred from beneficial effects on compressive strength. An equivalent NS addition into concrete with various w/b ratios did not produce similar effect on durability properties. No consistent trend as a function of w/b ratio was detected for the effectiveness of NS on durability properties of concrete, whilst effectiveness of NS addition on compressive strength decreased with decreasing w/b ratio.

5. Conclusions

This paper investigated the effects of NS on compressive strength and durability properties of concrete with various w/b ratios. From the results, the following conclusions can be drawn.(i)Beneficial effects of NS addition on compressive strength should not be taken as proof of similarly beneficial effects on durability properties.(ii)Effectiveness of a certain NS dosage on compressive strength and durability properties for high strength concrete mixes was different than low strength mixes. By the incorporation of 1.5% NS into concrete with , 0.55, and 0.5, strength gains of 41%, 6.5%, and nil, respectively, were obtained.(iii)Durability properties of concrete with different w/b ratios showed highly varying tendency by increasing NS dosage. For a certain NS dosage, analogous effect on concrete with different w/b ratios was not detected. Furthermore, the tendency of the variations as a function of w/b ratio was not preserved by increasing NS content.(iv)Sorptivity and water absorption exhibited negligible change after NS addition for and 0.5; only for they were clearly reduced by NS addition, having an optimum on 1%.(v)Apparent chloride diffusion coefficient of concrete decreased with 0.5% NS addition for and 0.55. However, it did not decrease with the addition of higher NS contents as effective as 0.5% NS. For , slight reduction was found only after 1.5% NS addition.(vi)The electrical resistivity of saturated specimen moderately increased after the addition of 0.5% NS for all w/b ratios. For , it also increased for 1.5% NS addition.(vii)NS addition resulted in detrimental effect on carbonation coefficient for and the carbonation coefficient was elevated from the reference of 24 to 29.3 mm/√year by 1% NS, in contrast to that of which was reduced from the reference of 20.4 to 16 mm/√year by the same NS content. Calcium hydroxide content of concrete was found to be reduced only in case of .(viii)NS clearly refined porosity microstructure of and 1% NS addition compared to reference. Limited refinement of macroporosity was observed by 1.5% NS addition to . Gel porosity of increased considerably with 1.5% NS addition.

Competing Interests

The authors declare that they have no competing interests.

Acknowledgments

The work received partial funding by the European IRSES project “Development of Sustainable Electrochemical Corrosion Protection Systems for Reinforced Concrete Structures” (DOSECOPS project) and the Shenzhen Strategic Emerging Industry Development Special Fund (no. JCYJ20150625102603853).