Research Article
Effects of Magnetite Aggregate and Steel Powder on Thermal Conductivity and Porosity in Concrete for Nuclear Power Plant
Table 1
Mix proportions for concrete test.
| Type | Unit content (kg/m3) | (%) | W | C | FA | G | S | WRA | MG | MS | SP |
| Control | 163 | 324 | 82 | 935 | 750 | 2 | 0 | 0 | 0 | 0 | M50M25 | 210 | 420 | 105 | 468 | 563 | 2 | 468 | 188 | 0 | 22.9 | M50M25S | 210 | 420 | 105 | 468 | 563 | 2 | 468 | 188 | 120 | 22.9 | M50M50 | 216 | 432 | 108 | 468 | 375 | 2 | 468 | 375 | 0 | 29.3 | M50M25S | 216 | 432 | 108 | 468 | 375 | 2 | 468 | 375 | 120 | 29.3 | M90M25 | 220 | 440 | 110 | 104 | 563 | 2 | 831 | 188 | 0 | 35.9 | M90M25S | 220 | 440 | 110 | 104 | 563 | 2 | 831 | 188 | 120 | 35.9 | M90M50 | 230 | 460 | 115 | 104 | 375 | 2 | 831 | 375 | 0 | 42.3 | M90M50S | 230 | 460 | 115 | 104 | 375 | 2 | 831 | 375 | 120 | 42.3 |
|
|
W: water, C: cement, FA: Fly Ash, G: gravel, S: sand, WRA: water reducing agent, MG: magnetite gravel, MS: magnetite sand, SP: steel powder, and : replacement ratio of volume.
|