Research Article

Comparative Study of Strength and Corrosion Resistant Properties of Plain and Blended Cement Concrete Types

Table 6

Potentiodynamic polarization parameters for the corrosion of rebar embedded in OPC, PPC, and PSC M40 grade concrete (90-day cured specimens).

System Various grades of concrete
M30 M40

(mV versus SCE)

(mA⋅cm−2) × 10−4
Corrosion rate (mmpy) × 10−3
(mV versus SCE)

(mA⋅cm−2) × 10−5
Corrosion rate (mmpy) × 10−4

OPC−3976.99228.0082−3012.14962.491
PPC−3031.69021.9589−2631.69021.9589
PSC−2991.44481.674−2581.44481.674