Research Article
Noise Gain Features of Fiber Raman Amplifier
Table 1
Noise figure
and output
of FRA in pure silica fiber (
= 50 km) at two backward pump powers. It is assumed that
= 1 mW and so
= −
[dBm].
| , −dBm | = 100 mW | = 300 mW | , dB | | , dB | | 1 | 2 | 3 | 4 | 5 |
| 18 | 0.002 | 4 ⋅ 10−5 | 0.013 | 4 ⋅ 10−5 | 19 | 0.003 | 4 ⋅ 10−6 | 0.016 | 4 ⋅ 10−6 | 20 | 0.004 | 3 ⋅ 10−7 | 0.020 | 3 ⋅ 10−7 | 21 | 0.005 | 10−8 | 0.026 | 10−8 | 21.5 | 0.005 | 10−9 | 0.029 | 2 ⋅ 10−9 | 22 | 0.006 | 2 ⋅ 10−10 | 0.032 | 2 ⋅ 10−10 | 22.5 | 0.007 | 10−11 | 0.036 | 2 ⋅ 10−11 | 23 | 0.008 | 9 ⋅ 10−13 | 0.041 | 10−12 | 23.5 | 0.008 | 4 ⋅ 10−14 | 0.046 | 5 ⋅ 10−14 | 24 | 0.009 | 10−15 | 0.05 | 2 ⋅ 10−15 | 25 | 0.012 | 3 ⋅ 10−19 | 0.06 | 5 ⋅ 10−19 | 27 | 0.02 | 3 ⋅ 10−29 | 0.1 | 9 ⋅ 10−29 | 30 | 0.04 | 4 ⋅ 10−56 | 0.2 | 4 ⋅ 10−54 | 35 | 0.12 | 10−169 | 0.6 | 6 ⋅ 10−152 | 40 | 0.36 | 0 | 1.7 | 0 | 50 | 2.7 | 0 | 7.6 | 0 |
| | 3 dB level at = 50.6 dB | 3 dB level at = 43.2 dB |
|
|