End-to-End Image Simulator for Optical Imaging Systems: Equations and Simulation Examples
Table 2
(a) Full Width Half Maximum (FWHM) values of SIMGA Spatial Response (across and along slit) obtained by static measurements performed in laboratory (Gaussian fit to data, [9]) and smearing effect due to integration during motion
FWHM (m) at 1 Km Across-SLIT (along-scan)
FWHM (m) at 1 Km Along-SLIT (across-scan)
VIS
1.91 (1.88 static)
1.05
SWIR
1.16 (1.13 static)
1.40
(b) SIMGA detector and optical parameters used for simulation ( = 30 m/s at 1 Km height)