Research Article

Energy Space Modeling of Power Electronics in Local Area Power Networks

Table 4

Local area power network model numeric solutions and measured values. In case (A), 𝑅 6 is 11.2  Ω with a load power 𝑃 6 = 50 W. In case (B) 𝑅 6 is 2.8  Ω with a load power 𝑃 6 = 140 W.

𝐼 1 𝐼 2 𝑉 3 𝑉 4 𝑉 5 𝑉 6

(A)Numeric
result
3.43 A1.76 A31.98 V30.94 V30.36 V30.19 V
Lab result3.48 A2.04 A32.4 V30.4 V29.8 V30.0 V

(B)Numeric result5.75 A2.96 A29.28 V27.51 V27.34 V24.42 V
Lab result5.60 A3.08 A30.0 V27.2 V27.0 V25.0 V