Research Article

Fabrication of PES/PVP Water Filtration Membranes Using Cyrene®, a Safer Bio-Based Polar Aprotic Solvent

Table 4

Thermogravimetric (TGA) analysis measurements of PES/C and PES/N membranes.

C/SampleResidue%Tm (°C)N/SampleResidueTm (°C)

PES302038589.7
PVP K905.3443.2
PES/C030.6588.7PES/N030.4572.9
PES/C0.132.3577.2PES/N0.124.1564.8
PES/C0.530.2588.5PES/N0.525.3569.2
PES/C130.2580.5PES/N130.5576.2
PES/C541.9568.2PES/N523.5546.7
PES/C1039.8580.7PES/N1022.8561.7