Research Article
Fabrication of PES/PVP Water Filtration Membranes Using Cyrene®, a Safer Bio-Based Polar Aprotic Solvent
Table 4
Thermogravimetric (TGA) analysis measurements of PES/C and PES/N membranes.
| C/Sample | Residue% | Tm (°C) | N/Sample | Residue | Tm (°C) |
| PES3020 | 38 | 589.7 | | | | PVP K90 | 5.3 | 443.2 | | | | PES/C0 | 30.6 | 588.7 | PES/N0 | 30.4 | 572.9 | PES/C0.1 | 32.3 | 577.2 | PES/N0.1 | 24.1 | 564.8 | PES/C0.5 | 30.2 | 588.5 | PES/N0.5 | 25.3 | 569.2 | PES/C1 | 30.2 | 580.5 | PES/N1 | 30.5 | 576.2 | PES/C5 | 41.9 | 568.2 | PES/N5 | 23.5 | 546.7 | PES/C10 | 39.8 | 580.7 | PES/N10 | 22.8 | 561.7 |
|
|