Charles Delaunay Institute, FRE CNRS 2848, University of Technology of Troyes, 10000 Troyes, France
Abstract
The aim of this paper was to compare empirical mode decomposition (EMD) and two new extended methods of EMD named complex empirical mode decomposition (complex-EMD) and bivariate empirical mode decomposition (bivariate-EMD). All methods were used to analyze stabilogram center of pressure (COP) time series. The two new methods are suitable to be applied to complex time series to extract complex intrinsic mode functions (IMFs) before the Hilbert transform is subsequently applied on the IMFs. The trace of the analytic IMF in the complex plane has a circular form, with each IMF having its own rotation frequency. The area of the circle and the average rotation frequency of IMFs represent efficient indicators of the postural stability status of subjects. Experimental results show the effectiveness of these indicators to identify differences in standing posture between groups.
1. Introduction
Falls are a major problem for the elderly due to the resulting loss of autonomy and subsequent behavior modification related to fear of falling. Health care services worldwide are actively working on the issue of falls for both medical and social reasons. For instance, in France alone, the number of deaths
attributed annually to falls is estimated to be more than 9000, with a
resultant cost in excess of two billion euros [1]. The cost of falls is only going to increase, in line with the increase in the elderly population. In Europe, the percentage of adults over
years old will
almost double from
to
by the year
[2]. Falling is a consequence of
a failure in the postural control system due to aging or a specific pathology.
Many risk factors have been identified for falls, the most commonly cited
including an underlying muscular weakness, a previous fall, as well as balance
and gait problems [3].
Postural equilibrium is maintained by reacting to
information from the different sensory systems, including vestibular, visual,
and proprioception systems. It is possible to evaluate the postural control
system using either clinical or biomechanical tests. Biomechanical tests can be
dynamic or static, with dynamic tests used to characterize the performance of
the postural control system to maintain the posture after an external
perturbation. In contrast, static tests evaluate postural performance in a
static position. In static posture, a force plate is used to evaluate postural
sway. The force plate measures the displacement of the center of pressure
(COP), which represents the location of the resultant force exerted on the
surface of a force plate. The COP, which can be used as a measure of postural
stability, is measured in the horizontal plane in both anteroposterior (AP) and
mediolateral (ML) directions [4]. The representation of the COP time series in AP and
ML directions is known as the stabilogram (see Figure 1).
Figure 1: Displacement of the center of pressure in the
horizontal plane (bottom left), displacement in the anteroposterior direction
over time (top right), and displacement in the mediolateral direction over time
(bottom right). Data are recorded from a healthy control subject for 10
seconds.
Traditional parameters are extracted from the
stabilogram signals under the assumption that the COP is a stationary time
series [4, 5]. These classical parameters
give few insights into the control of posture [6], providing purely statistical information while ignoring the dynamic characteristics of COP displacements. These parameters include temporal (mean, RMS), spatiotemporal
(area of the ellipse), and spectral (median frequency) parameters.
Recently, parameters that describe the fractal and
time evolutionary properties of the COP and provide information related to
underlying physiological control processes have been extracted using nonlinear
and fractal analyses. These new groups of parameters include the Hurst
exponent, which provides information about long-term correlation [7], the reconstructed phase
space [8], and entropy
[9].
Stabilogram signals have been shown to be
nonstationary signals [10, 11]. In order to extract information from the stabilogram
and to characterize the postural stability, it is proposed in this paper to
apply the Hilbert transform on the intrinsic mode functions (IMFs) extracted by
the empirical mode decomposition (EMD) [12]. The EMD method decomposes the signal into a set of
IMFs which represent the oscillatory modes embedded in the signal. For the COP
signal, IMFs have well-defined instantaneous frequency and different IMFs do
not exhibit the same frequency at the same time. In addition, the COP signal is
a bidirectional signal and can be represented by a complex signal
. The two components of the COP signal are nonlinearly correlated due to the complex
correlation between all the postural control systems. To analyze the complex
COP signal, two new methods derived from EMD method to decompose a complex
signal will be applied. The first method, complex empirical mode decomposition
(complex-EMD), was developed in [13], while the second method, bivariate empirical mode
decomposition (bivariate-EMD) was developed in [14, 15].
The complex-EMD method is based on the inherent relationship between the positive and negative frequency components of a complex signal. This method treats the positive and negative frequency
components as two independent signals. The EMD of these two components gives
two sets of IMFs corresponding to the positive and negative frequency
components of a complex signal. The bivariate-EMD method is based on the idea
of replacing the oscillation notion in EMD by a notion of rotation. This method
considers that the bivariate signal can be described as the sum of a fast
rotation component superimposed on a slower rotation. The bivariate-EMD
algorithm consists in projecting the complex signal on a set of directions and
then applying the sifting process of the basic-EMD on the projected components.
The EMD, complex-EMD, and bivariate-EMD methods are
powerful signal processing techniques that can be used to analyze the
stabilogram and to characterize the quality of equilibrium in standing posture.
In fact, the plots of the analytic IMFs in the complex plane have a specific
geometry similar to a circular form; and each IMF has its own rotation
frequency. In contrast, the analytic signal of the entire stabilogram signal
does not have a specific form, and it differs between experiments for the same
subject due to its inherent nonstationary nature. Furthermore, the stabilogram
is a multicomponent signal, thus its instantaneous frequency cannot be
calculated directly. These two features (circular form and rotation frequency)
permit the extraction of new nonlinear parameters that characterize the quality
of equilibrium and provide more information about the mechanisms underlying
postural control. The first parameter is simply the area of the circle formed
by the shape of the analytic IMF, while the second parameter is the average
rotation frequency.
In order to test the capacity of different EMD methods and the Hilbert transform to describe the quality of equilibrium and to
discriminate between elderly and control group, the three EMD methods were
applied on stabilogram signals extracted from elderly and control groups. The
extracted nonlinear parameters from the plots of the analytic IMFs were the
area of the circle in the complex plane, and the average rotation frequency of each
IMF. The paper is organized as follows. The experimental protocol, EMD,
complex-EMD, bivariate-EMD, and the parameter calculation are presented in
Section 2. The results of the application of the cited methods on the stabilogram are presented in Section 3. Discussions about the results and the EMD methods are presented in Section 4.
2. Methods
2.1. Subjects
Ten healthy control subjects (three males and seven females) and ten healthy elderly subjects (four males and six females) participated in the study. Control
subjects' mean age, height, and weight were
y,
cm, and
kg, respectively. Elderly subjects' mean age, height and weight were
y,
cm, and
kg, respectively. All subjects who participated gave
their written informed consent. No subjects reported any musculoskeletal or
neurological conditions that precluded their participation in the study.
2.2. Data Acquisition and Data Processing
Center of pressure data were obtained from a Bertec 4060–08 force plate
(Bertec Corporation, Columbus, Ohio, USA). The initial COP signals were
calculated with respect to the center of the force plate before normalization
by subtraction of the mean value. Data were recorded using ProTags and
developed in Labview (National Instruments Corporation, Austin, Tex, USA). Data
were sampled at 100 Hz, using an 8th-order lowpass Butterworth filter with a
cutoff frequency of 10 Hz. All subsequent calculations were performed using
MATLAB (Mathworks Inc, Natick, Mass, USA).
2.3. Experimental Protocol
Subjects were tested barefoot or wearing socks. Testing began with subjects standing upright with their arms by their sides in front of the force-plate while looking at a
-cm cross fixed on the wall two meters in front of them. Upon verbal instruction, subjects stepped onto the force-plate. Subjects were not required to use a preordained foot position. Data recording lasted 15 seconds, during which time subjects maintained an upright posture. A second verbal command was given for subjects to step down from the force plate.
2.4. Empirical Mode Decomposition
EMD is a signal processing decomposition technique that decomposes the signal into waveforms modulated in both amplitude and frequency by extracting all of the oscillatory modes embedded in the signal [12]. The decomposition is an intuitive and adaptive signal-dependent decomposition and does not require any conditions about the stationarity and linearity of the signal. The waveforms extracted by EMD are named IMFs. Each IMF is symmetric, is assumed to yield a meaningful local frequency, and different IMFs do not exhibit the same frequency at the same time. In other words, each IMF satisfies the two following constraints:
(i)
the number of extrema and the number of zero crossings are identical or differ at most by one;
(ii)
the mean value
between the upper and the lower envelope is equal to zero at any time.
The difference between the original signal and the IMF time series is the residual. The first IMF component is obtained by a sifting process. This procedure is then applied on the residual in order to extract the
second IMF, and so forth. Thus all the IMFs are iteratively extracted. The
nonstationary signal
is then represented as a linear sum of IMFs and the residual component:
(1)where
denotes the
extracted
empirical mode and
the residual.
The EMD algorithm can be summarized as follows.
(1) Extract all the
extrema of
.(2)Interpolate
between minima (resp., maxima) to obtain two envelopes
and
.(3) Compute the
average:
.(4)Extract the
detail
.(5) Test if
is an IMF:
(i)if
yes, repeat the procedure from the step 1 on the residual signal
,(ii)if
not, replace
with
and repeat the
procedure from step 1.
Matlab codes are available at
http://perso.ens-lyon.fr/patrick.flandrin/emd.html.
An example of the application of EMD on the 10-second
AP time series traced in Figure 1 is shown in Figure 2. The number of IMFs varied between experiments and between subjects. The minimum number of IMFs was 4.
Figure 2: EMD decomposition of the 10-second anteroposterior
displacement time series in Figure
1.
2.5. Hilbert Transformation and Phase Estimation
The Hilbert transform of a real signal
is defined as
(2)
where
indicates the Cauchy principle value. The analytic signal of
is then defined as:
(3)
The analytic signal can be further expressed
as
(4)
where
is the
amplitude of
, and
is the
instantaneous phase from which the instantaneous signal frequency
is obtained by differentiation:
(5)
The original signal
is now
expressed in a Fourier-like expansion as
(6)in which the residual
is included and where the index
refers to each IMF and
denotes the real part of a complex quantity. Huang etal. proposed that the Hilbert transform should be applied on all IMFs obtained by EMD. This transform is known as Hilbert-Huang transform (HHT). Indeed, the IMFs are locally symmetric functions and therefore the instantaneous frequency is well localized in the time-frequency domain.
An example of the HHT (with scalar EMD) applied on two
AP time series is presented in Figure 3. The first AP time series was recorded from a healthy control subject (black lines), while the second time series was recorded from a healthy elderly subject (grey lines). This figure presents the trace of the entire analytic signal in the complex plane (Figure 3(a)), as well as those
of each analytic IMF extracted with the basic-EMD (Figures 3(b)–3(e)). It can be seen that
the forms of these traces are similar to circles. A discussion about this
figure is presented in the discussion section.
Figure 3: Representation in the complex plane of the analytic
signal of a healthy control subject (black lines) and healthy elderly subject
(grey lines) for the AP direction (a). Analytic signals of the first four IMFs
(b): IMF1, (c): IMF2, (d): IMF3, and (e): IMF4.
In Figure 4, the phase time series of each IMF and the average rotation frequencies of a control subject are presented. The average rotation frequency is equal to the slope estimate of the phase time series divided by
. It can be observed that the average rotation frequency decreases from the first IMF to the last IMF simply because the
sifting procedure picks the component with the fastest variation embedded in
the original signal first and that with the slowest variation last.
Figure 4: Traces of the instantaneous phase and the
value of the average rotation frequency for the first four IMFs of the AP
displacement traced in Figure
2.
2.6. Complex Empirical Mode Decomposition
The complex-EMD is an extension of the basic-EMD suitable for dealing with complex signals [13]. The motivation
to extend EMD is that a large number of signal processing applications have
complex signals. In addition, this extension is applied on both the real and
imaginary parts simultaneously because complex signals have a mutual dependence
between the real and imaginary parts. Thus, if the decomposition is done
separately, the mutual dependency will be lost. The algorithm of the
complex-EMD is as follows.
(1)Extract the
positive and negative frequency components to generate two analytic signals
and
as follows:
(7)
where
is an ideal
bandpass filter equal to one for
and zero for
,
is the complex
conjugate of
.(2)Extract the real part of the inverse Fourier transform of
and
, denoted by
and
.(3)Apply the basic-EMD on
and
separately to extract the IMFs of the positive and negative components denoted by
and
.
Finally,
and
can be expressed as
(8)
where
and
are the
residuals of
and
, respectively.
The complex-EMD can now be expressed as
(9)
where
, and
denotes the
Hilbert transform operator.
2.7. Bivariate Empirical Mode Decomposition
Bivariate-EMD is another extension of the EMD to complex signals. The main difference between the bivariate-EMD and the complex-EMD is that the latter uses the basic-EMD to decompose complex signals, whereas the bivariate-EMD adapts the rationale underlying the EMD to a bivariate framework [14, 15]. The algorithm of the bivariate-EMD, as proposed in [14], is as follows:
(1)For
,
(a)project
on direction
,(b)extract the maxima of
(c)interpolate the set of points
to obtain the
partial envelope curve in direction
named
(2)Compute the mean of all tangents as follows:
.(3)Subtract the
mean to obtain
.(4) Test if
is an IMF:
(a) if
yes, repeat the procedure from the step 1 on the residual signal,(b)if
not, replace
with
and repeat the
procedure from step 1.
The bivariate-EMD can now be expressed as
(10)
where
denotes the
extracted
complex empirical mode and
the residual.
2.8. Parameter Calculation
Two types of parameters were calculated from the decomposition of COP signals into IMFs using the three methods of decomposition, EMD, complex-EMD, and bivariate-EMD. The first parameter is related to the form of the analytic IMFs in the complex plane, which can be seen to be circular. The parameter extracted is the area of the circle in which
of the data points are located
. This parameter was calculated for each of the first four IMFs. The second parameter, which is related to the phase of the analytic IMFs, is the average rotation frequency
of the analytic IMFs in the complex plane. These parameters were calculated for both AP and ML directions for the basic-EMD method and for
for the complex-EMD and bivariate-EMD methods. For each COP signal, a total of 24 areas and 24 frequencies were calculated using the three different methods. For the bivariate-EMD, we have used
projections.
2.8.1. Data Analysis
Center of pressure data were calculated from the moment the
second foot contacted the force plate
.
was calculated
as the time at which the maximum value of the second derivative of the ML
signal occurred, which corresponded to the time the second foot touched the
force plate. At this point, the largest acceleration of ML would occur when the
COP moved rapidly towards the second foot. This instant in time was used for
both AP and ML displacements. All analyses were performed for the 10-second
period starting 1 second after
, in order to give both AP and ML displacement time to
return to near central values. The choice of
has been
validated in previous work [7]. Statistical analyses were performed with the
statistical package for social sciences (SPSS Inc., Chicago, Ill, USA). The
Kolmogorov-Smirnov test was used to check for normality. Owing to the grossly
non-normal distribution of the area parameters
, it was
necessary to apply a log transformation to all
in order that
an analysis of variance (ANOVA) could be performed. ANOVA was used to compare
results between conditions, with
and
as the
dependent variables and the subject group as the independent variable. Alpha
level was set at
.
3. Results
There was a significant difference in
values between
groups for all IMFs for all three methods (basic-EMD for AP and ML, complex-EMD
for negative and positive components, and bivariate-EMD for real and imaginary
parts) (Figure 5). The area was greater for elderly subjects then for control subjects. These increases in the values of
are indicative
of degradation in the balance due to the effect of age on postural stability.
Figure 5: The surface area of the analytic signal in a
logarithmic scale

of the first
four IMF for control and elderly subjects. (a) EMD for AP displacement; (b) EMD
for ML displacement; (c) bivariate-EMD for the imaginary part of the signal
(corresponding to AP displacement); (d) bivariate-EMD for the real part of the
signal (ML); (e) complex-EMD for positive components; and (f) complex-EMD for
negative components. Data are mean and

confidence
intervals. All comparisons are significantly different between groups.
In respect to the average rotation frequency
parameters, significant differences were observed for the basic-EMD for AP displacement for both IMF1 and IMF2, with smaller values observed for elderly subjects (Figure 6(a)). In respect to ML displacement for basic-EMD, significant differences
were observed between elderly and control subjects for IMF1, IMF2, and IMF3
(Figure 6(b)). For the bivariate-EMD method, significant differences were observed
only for IMF3 for the real part corresponding to ML (Figure 6(d)), and for IMF1 for the imaginary part corresponding to AP (Figure 6(c)). However, for the complex-EMD, the average rotation frequency was significantly different for all IMFs for both positive and negative components (Figures 6(e), 6(f)). The rotation frequency was lower for elderly subjects then for the control subjects.
Figure 6: The average rotation frequency

of the first
four IMF for control and elderly subjects. (a) EMD for AP displacement; (b) EMD
for ML displacement; (c) bivariate-EMD for the imaginary part of the signal
(corresponding to AP displacement); (d) bivariate-EMD for the real part of the
signal (ML); (e) complex-EMD for positive components ; and (f) complex-EMD for
negative components. Data are mean and

confidence
intervals.
*Significant difference from control subjects.
4. Discussion
The first point to be addressed is whether the use of the EMD methodology followed by the Hilbert transform, as used in the present study, provides greater insight than simply applying the Hilbert transform to the whole signal, which also detected significant differences in surface area between groups. The response is related to the nature of the trace of the analytic signal of whole signal. It can be observed in Figure 3(a) that the analytic signal in the complex plane does not
have a specific geometry, making it impossible to define the circle that
encloses
of the data
points. In addition, the form of the analytic trace differs between experiments
for the same subject, as well as between subjects. Such a tracing is indicative
of multiple centers of rotation, possibly due to the presence of several
different control strategies. In contrast, the traces of the analytic signals
of each IMF always have a circular form (Figures 3(b)–3(e)), the area of which
can then be estimated in the complex plane.
In respect to average rotation frequency, the trace of
the phase as a function of time indicates a linear relation between phase and
time. This relationship confirms the existence of a harmonic oscillation with a
constant frequency equal to the average frequency. In addition, all the EMD
methods permit the extraction of a proper rotation that could be related to
different postural control systems.
In respect to the interpretation of the results for
the postural data of the present study, elderly subjects had significantly
greater surface areas for both AP and ML displacement than did the control
subjects. The increased surface areas observed for the elderly subjects were
due to the greater amplitude of postural sway for elderly subjects for all
IMFs, thus indicating a less well-controlled posture.
In respect to the rotation frequency, in contrast to
surface area, smaller values were observed for elderly subjects. This contrast
is self-explanatory, as surface area and rotation frequency are negatively
correlated. Given that the time-series length is the same for the both groups,
it follows that if the radius of the circle is greater, the rotation frequency
will be smaller.
4.1. Comparison between One-Dimensional and Two-Dimensional EMD Methods
For the one-dimensional EMD method, the mutual dependence between the real and imaginary parts of the complex signal is lost and is mapped onto two real
independent signals that are decomposed separately. In the case of the
stabilogram, AP and ML displacements are decomposed separately in the
basic-EMD, despite the fact that the same postural control systems produce
these two signals. It is almost certain that these two signals are linearly
and/or nonlinearly correlated. In addition, physiological interpretation could
be difficult as mutual information is lost.
The complex-EMD method decomposes the positive and
negative components separately, as for two independent signals. The IMFs
resulting from the positive and negative components form two independent sets
of IMFs for which it is not necessary that the number of IMFs is equal for
positive and negative components. However, interpretation of the positive and
negative frequency is difficult as the positive and negative components bear no
obvious relationship with physiological control systems. Despite this,
complex-EMD was the only method that enabled discrimination between elderly and
control groups using the average rotation frequency for all of the first four
IMFs for both positive and negative frequency components. Confirmation of the
capacity of the complex-EMD method to detect differences between groups based
on average rotation frequencies was performed using data from an experimental
study in which the proprioceptive and visual systems were degraded by applying
tendon vibration, and by closing subjects' eyes. Details of the experiments
performed on 17 healthy young subjects can be found in [16]. The same EMD, complex-EMD,
and bivariate-EMD analyses were applied on the data
from these experiments. In respect to the area, similar results were obtained between
groups, with greater surface areas and thus increased postural sway observed
for vibration. In respect to the average rotation frequency, the complex-EMD
method again outperformed the two others, with significant differences observed
between groups for all four IMF for both positive and negative rotation (Figure 7). In contrast, for the basic-EMD method, significant differences were
observed for all IMFs for AP displacement and for the first and second IMFs for
ML displacement. With respect to the bivariate-EMD method, only three of the
IMFs for AP and two of the IMFs for ML showed significant differences between
groups (Figure 7). Furthermore, the IMFs in which these differences were
observed were not the same as those identified in Figure 6 for the control and
elderly subjects.
Figure 7: The average rotation frequency

of the first
four IMF for control and vibration subjects. (a) EMD for AP displacement; (b)
EMD for ML displacement; (c) bivariate-EMD for the imaginary part of the signal
(corresponding to AP displacement); (d) bivariate-EMD for the real part of the
signal (ML); (e) complex-EMD for positive components; and (f) complex-EMD for
negative components. Data are mean and

confidence
intervals.
*Significant difference from control subjects.
In addition, we have studied the influence of
different values of
(from
to
) on the
ability of the bivariate-EMD to discriminate between groups. The statistical
significance of results is unaltered for the surface parameter
for the
different values of
. However, varying the value of
may cause the
change of the statistical significance of the average rotation frequency to
discriminate between groups. The statistical significance is lost for certain
IMFs and may appear for other IMFs while varying the value of
.
The difference between results is not surprising for
the bivariate-EMD method. This method is based on the rotation in
two-dimensional space, while the extraction of extrema is related to the change
of the moving point direction [15]. Due to this fundamental difference in methodology,
the results for the average rotation frequency are not the same for the
bivariate-EMD.
In respect to the sifting process used by the
different methods, complex-EMD uses the basic-EMD method. The only difference
is that the complex-EMD decomposes the complex signal into two positive and
negative frequency components before applying the sifting process.
Concerning the bivariate-EMD method, despite the less
impressive results shown in the present study when compared to the complex-EMD
method, bivariate-EMD might offer some advantages under specific conditions.
For instance, rather than split the complex signal into two parts, the
bivariate-EMD decomposition is done on the complex signal directly, thus the
problem of the number of IMFs for the positive and negative frequency
components does not arise due to the unified approach adopted to decompose the
complex signal. In addition, the mutual dependency between the real and
imaginary parts of the complex signal is taken into account. In this way,
bivariate-EMD might be more likely to respond to changes in spatial parameters
than the others methods. Furthermore, bivariate-EMD enables the extraction of
the fast rotation that is superimposed on slower rotation in the COP signals.
In this way, it could be possible to identify the characteristics of different
posture control systems in future studies.
5. Conclusion
The EMD, complex-EMD, and bivariate-EMD methods are useful and powerful methods to analyze nonstationary univariate and bivariate time series. In the case of
stabilogram time series, these methods were able to extract the oscillations in
different adaptive time scales, and to define proper rotations that could be
related to the different postural control systems. In addition, these methods
enabled the quality of equilibrium of postural systems to be characterized as
well as to identify the differences in postural control mechanisms between
elderly and control subjects. In fact, the use of the different types of EMD
methods enabled the extraction of individual centers of rotation for each IMF.
In perspective, additional work is planned in order to find the relation
between IMFs and the different postural control systems. A follow-up study will
address this issue, initially by simulation, before using different
experimental conditions in which the different postural control systems will be
impaired. The aim of this study will be to ascertain whether or not each IMF
corresponds to a given postural control system.
Acknowledgments
This study was undertaken as part of the mv-EMD research project (multivariate Empirical Mode Decomposition) supported by the French ANR agency (ANR Blanc Grant BLAN07-1_223026), the PréDICA research project (Prévision, Détection Investigation contre la Chute des Personnes Âgées) supported by the French ANR agency (Grant ANR-O5-RNTS-01801), and the PARAChute research project (Personnes Agées et Risque de Chute) which was supported in part by The French Ministry of Research (Grant 03-B-254), The European Social Fund (Grant 3/1/3/4/07/3/3/011), The European Regional Development Fund (Grant 2003-2-50-0014 and Grant 2006-2-20-0011), The Champagne-Ardenne Regional Council (Grant E200308251), and INRIA (Grant 804F04620016000081).
References
- Comité Français d'Education pour la Santé, “Les clés du “bien vieillir”: prévention des chutes chez les seniors,” November 2001, Caisse Nationale de l'Assurance Maladie des Travailleurs Salariés.
- “The 2005 epc projections of age-related expenditure (2004-50) for the eu-25 member states,” European Commission, Luxembourg, 2005.
- L. Z. Rubenstein and K. R. Josephson, “The epidemiology of falls and syncope,” Clinics in Geriatric Medicine, vol. 18, no. 2, pp. 141–158, 2002.
- T. E. Prieto, J. B. Myklebust, R. G. Hoffmann, E. G. Lovett, and B. M. Myklebust, “Measures of postural steadiness: differences between healthy young and elderly adults,” IEEE Transactions on Biomedical Engineering, vol. 43, no. 9, pp. 956–966, 1996.
- T. E. Prieto, J. B. Myklebust, and B. M. Myklebust, “Characterization and modeling of postural steadiness in the elderly: a review,” IEEE Transactions on Rehabilitation Engineering, vol. 1, no. 1, pp. 26–34, 1993.
- J. J. Collins and C. J. De Luca, “Upright, correlated random walks: a statistical-biomechanics approach to the human postural control system,” Chaos, vol. 5, no. 1, pp. 57–63, 1995.
- H. Amoud, M. Abadi, D. Hewson, V. Michel-Pellegrino, M. Doussot, and J. Duchêne, “Fractal time series analysis of postural stability in elderly and control subjects,” Journal of NeuroEngineering and Rehabilitation, vol. 4, pp. 1–12, 2007.
- H. Snoussi, H. Amoud, M. Doussot, D. Hewson, and J. Duchêne, “Reconstructed phase spaces of intrinsic mode functions. Application to postural stability analysis,” in Proceedings of the 28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBS '06), pp. 4584–4589, New York, NY, USA, August-September 2006.
- H. Amoud, H. Snoussi, D. Hewson, M. Doussot, and J. Duchêne, “Intrinsic mode entropy for nonlinear discriminant analysis,” IEEE Signal Processing Letters, vol. 14, no. 5, pp. 297–300, 2007.
- J. P. Carroll and W. Freedman, “Nonstationary properties of postural sway,” Journal of Biomechanics, vol. 26, no. 4-5, pp. 409–416, 1993.
- G. F. Harris, S. A. Riedel, D. Matesi, and P. Smith, “Standing postural stability assessment and signal stationarity in children with cerebral palsy,” IEEE Transactions on Rehabilitation Engineering, vol. 1, no. 1, pp. 35–42, 1993.
- N. E. Huang, Z. Shen, S. R. Long, et al., “The empirical mode decomposition and the Hilbert spectrum for nonlinear and non-stationary time series analysis,” Proceedings of the Royal Society of London A, vol. 454, no. 1971, pp. 903–995, 1998.
- T. Tanaka and D. P. Mandic, “Complex empirical mode decomposition,” IEEE Signal Processing Letters, vol. 14, no. 2, pp. 101–104, 2007.
- G. Rilling, P. Flandrin, P. Gonçalves, and J. M. Lilly, “Bivariate empirical mode decomposition,” IEEE Signal Processing Letters, vol. 14, no. 12, pp. 936–939, 2007.
- M. U. Bin Altaf, T. Gautama, T. Tanaka, and D. P. Mandic, “Rotation invariant complex empirical mode decomposition,” in Proceedings of the IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP '07), vol. 3, pp. 1009–1012, Honolulu, Hawaii, USA, April 2007.
- V. Michel-Pellegrino, H. Amoud, D. Hewson, and J. Duchêne, “Identification of a degradation in postural equilibrium invoked by different vibration frequencies on the tibialis anterior tendon,” in Proceedings of the 28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBS '06), pp. 4047–4050, New York, NY, USA, August-September 2006.