Research Article

Effect of Temperature and Electric Field on the Damping and Stiffness Characteristics of ER Fluid Short Squeeze Film Dampers

Figure 4

Direct stiffness coefficient, , (MN/m) versus temperature, (°C) for (a)  kV/mm, and (b)  kV/mm under a constant strain rate,  s−1.
526428.fig.004a
(a)
526428.fig.004b
(b)