Research Article
Dynamic Mechanical Response of Biomedical 316L Stainless Steel as Function of Strain Rate and Temperature
Table 6
Variation of deformation-induced temperature rise as function of temperature and strain rate.
| (°C) | Strain rate (s−1) | Temperature rise ΔT (K) | | | | | |
| 25 | 5000 | 12.83 | 27.85 | 61.76 | 99.33 | 139.72 | 3000 | 12.48 | 27.06 | 59.80 | 85.3 | 121.2 | 1000 | 10.29 | 22.31 | 53.2 | 79.4 | 100.3 |
| 200 | 5000 | 11.94 | 25.86 | 57.12 | 91.54 | 128.37 | 3000 | 11.13 | 24.05 | 52.85 | 82.36 | 109 | 1000 | 9.85 | 21.32 | 50.2 | 73.4 | 95.6 |
| 400 | 5000 | 10.96 | 23.54 | 51.41 | 81.76 | 113.95 | 3000 | 10.26 | 22.00 | 47.91 | 75.97 | 99.4 | 1000 | 9.22 | 19.89 | 39.3 | 65.9 | 89.6 |
| 800 | 5000 | 8.38 | 17.62 | 37.52 | 58.68 | 80.78 | 3000 | 7.81 | 16.49 | 35.25 | 55.23 | 76.10 | 1000 | 7.15 | 15.19 | 34.2 | 51.3 | 72.1 |
|
|