Clinical Study
Clinical Evaluation of CyberKnife in the Treatment of Vestibular Schwannomas
Table 4
Comparison of patients with worse hearing and preserved hearing.
| | Patients with worse hearing () | Patients with preserved hearing () |
| Tumor volume (mm3) | 6845.2 ± 6704.4 | 4047.3 ± 4441.7* | Cochlear Volume (mm3) | 26.8 ± 13.8 | 51.0 ± 64.9* | Dose to the cochlear (cGy) | | | Maximum | 1525.7 ± 434.8 | 1207.9 ± 409.3 | Minimum | 919.3 ± 484.1 | 649.1 ± 304.9 |
|
|
versus patients with worse hearing.
|