Review Article

Role of Stenting for Intracranial Atherosclerosis in the Post-SAMMPRIS Era

Table 1

Summary of endovascular stenting series for the treatment of intracranial atherosclerosis published after SAMMPRIS.

SeriesYearType of stentNumber of patients (lesions)Minimum arterial stenosisTechnical success rateMean/median clinical follow-up duration (months)Rate of postprocedural ischemia (ipsilateral)Rate of postprocedural ischemia (all)Rate of symptomatic in-stent restenosis

Gandini et al. [20]2013Wingspan21 (42)70%100%204.8%4.8%0
Jin et al. [33]2013Multiple1226 (233)NRNR3911.6%11.6%5.2%
Park et al. [18]2013Cypher11 (11)50%100%67000
Rohde et al. [21]2013Multiple2100 (100)50%94.0%1NR25%NR
Yu et al. [17]2013Wingspan95 (95)70%93.7%413.1% in 30 days, 0% from 30 days to 1 year9.5% in 1 yearNR
Zhang et al. [19]2013Wingspan61 (61)70%98.4%2410.0%11.7%3.3%
Jiang et al. [28]2012Multiple3637 (670)50%94.6%NR5.8% at 30 days, 13.7% overall5.8% at 30 days, 13.7% overall11.1%
Kim et al. [22]2012Multiple477 (85)50%87.1%297.7%9.2%3.1%
Kurre et al. [31]2012Multiple5397 (409)50%98.0%ā€‰NR11.6%NR
Li et al. [30]2012Wingspan30 (31)70%100%1813.3%16.7%5.3%
Mohammadian et al. [24]2012Multiple634 (34)70%97.0%152.9%5.8%0
Tarlov et al. [26]2012Multiple741 (41)50%100%14NR20.0%7.5%
Vajda et al. [29]2012Enterprise189 (209)50%99.5%72.3%7.7%2.3%
Vajda et al. [23]2012Coroflex Please95 (106)50%93.4%161.9%3.8% in 30 days, 0.9% after 30 days0
Yu et al. [27]2012Wingspan57 (57)50%93.0%NRNR8.8%NR
Zhang et al. [25]2012Wingspan53 (53)50%98.1%186.0%10.0%4.0%
Costalat et al. [32]2011Wingspan60 (63)50%95.2%136.3%6.3%2.0%
Park et al. [34]2011FlexMaster12 (14)70%100%9000

NR: not reported.
Multiple stents were used in this study including Wingspan (Boston Scientific), Apollo (MicroPort Medical), and coronary balloon-expandable stents.
Multiple stents were used in this study including AVE (Medtronic), Neurolink (Guidant), Neuroform (Boston Scientific), and Wingspan (Boston Scientific) stents.
Multiple stents were used in this study including Vision (Abbott), Mini-Vision (Abbott), Penta (Abbott), Taxus Express (Boston Scientific), Cypher (Cordis Corp), S70 (Medtronic), Driver (Medtronic), Apollo (MicroPort Medical), BiodivYsio (Biocompatibles), and Wingpan (Boston Scientific) stents.
Multiple stents were used in this study including Endeavor (Medtronic), Vision (Abbott), FlexMaster (Abbott), Arthos pico (AMG International), Neuroform (Boston Scientific), Tsunami (Terumo), and Driver (Medtronic) stents.
Multiple stents were used including Wingspan (Boston Scientific), LEO (BALT Extrusion), Neuroform (Boston Scientific), Enterprise (Cordis Corp), Xpert (Abbott), Pharos (Micrus), BOA (BALT Extrusion), Apollo (MicroPort Medical), Arthos (AMG), AVE S660 and S670 (Medtronic) BX Sonic and Velocity (Cordis Corp), Cerebrence (Medtronic), Coroflex blue (Braun), Driver (Medtronic), Endeavour (Medtronic), FlexMaster (Abbott), INX (Medtronic), Lekton Motion (Biotronik), Multi-Link (Abbott), S7 (Medtronic), Taxus Express and Liberte (Boston Scientific), Tecnic carbostent (Sorin Biomedica), and Tsunami Gold (Terumo) stents.
Multiple stents were used including balloon-mounted, coronary bare metal stent for internal carotid artery stenosis, and self-expanding stents for middle cerebral artery stenosis.
Multiple stents were used including Wingspan (Boston Scientific), AVE (Medtronic), ACS, Voyager (Abbott), Vision (Abbott), Palmaz-Schatz (Cordis Corp), Multilink (Abbott), and other Guidant and Medtronic stents.