Research Article

Physical Properties of Polyamide-12 versus PMMA Denture Base Material

Table 2

Modulus of elasticity (MPa) of polyamide-12 specimens ( ). Modulus of elasticity of dry specimens after delivery from the dental laboratory differed significantly from values after 1000, 3000, and 7000 thermocycles and wet storage.

MPaAfter delivery
(dry storage)
After 1000 thermocycles
(wet storage)
After 3000 thermocycles
(wet storage)
After 7000 thermocycles
(wet storage)

Mean1084828848845
SE21131612
Min870708742780
Max1178885981960