Clinical Study

Speckle-Tracking and Tissue-Doppler Stress Echocardiography in Arterial Hypertension: A Sensitive Tool for Detection of Subclinical LV Impairment

Table 6

Speckle-tracking and tissue-Doppler: Strain rate at rest and during stress testing; -values are calculated with the Mann-Whitney--test.

Hypertensive ()Control ()-value

At rest
STE (entire septum)−1.25 SD 0.57−1.28 SD 0.210.037
STE (basal septum)−1.22 SD 0.42−1.17 SD 0.31NS
TDI (entire septum)−1.16 SD 0.19−1.37 SD 0.27<0.001
TDI (basal septum)−1.24 SD 0.27−1.39 SD 0.370.030

50 Watts
STE (entire septum)−1.65 SD 0.36−1.86 SD 0.330.002
STE (basal septum)−1.56 SD 0.56−1.72 SD 0.49NS
TDI (entire septum)−1.55 SD 0.25−2.00 SD 0.39<0.001
TDI (basal septum)−1.63 SD 0.30−2.06 SD 0.42<0.001

150 Watts
STE (entire septum)−1.87 SD 0.37−2.35 SD 0.53<0.001
STE (basal septum)−1.93 SD 0.63−2.30 SD 0.640.004
TDI (entire septum)−1.85 SD 0.30−2.42 SD 0.49<0.001
TDI (basal septum)−1.85 SD 0.41−2.55 SD 0.65<0.001