Arthroscopic Fixation of Cell Free Polymer-Based Cartilage Implants with a Bioinspired Polymer Surface on the Hip Joint: A Cadaveric Pilot Study

Table 2

Results of two scaffold fixation techniques on two human cadavers after 50 cycles of continuous motion.

MaterialFixation techniqueOutline attachment
50 cycles average score
(±standard deviation)
Area coverage
50 cycles average score
(±standard deviation)
Scaffold integrity
50 cycles average score
(±standard deviation)
Endpoint fixation
50 cycles average score
(±standard deviation)

PGA-scaffoldUnfixed1.0 (±0)1.5 (±0.7) 1.0 (±0) 0.5 (±0.7)

PGA-PM-scaffoldUnfixed 2.0 (±0)*2.0 (±0) 1.0 (±0) 2.0 (±0)*

PGA-scaffoldFixed with fibrin glue 2.5 (±0.7)2.5 (±0.7) 3.0 (±0.7) 2.0 (±0.0)

PGA-PM-scaffoldFixed with fibrin glue 3.5 (±0.7)*3.5 (±0.7)* 4.0 (±0.7)* 3.0 (±0.0)*

Average per scoring item for the scaffold fixation techniques after 50 cycles (*).