Table 2
Results of two scaffold fixation techniques on two human cadavers after 50 cycles of continuous motion.
| Material | Fixation technique | Outline attachment 50 cycles average score (±standard deviation) | Area coverage 50 cycles average score (±standard deviation) | Scaffold integrity 50 cycles average score (±standard deviation) | Endpoint fixation 50 cycles average score (±standard deviation) |
| PGA-scaffold | Unfixed | 1.0 (±0) | 1.5 (±0.7) | 1.0 (±0) | 0.5 (±0.7) |
| PGA-PM-scaffold | Unfixed | 2.0 (±0)* | 2.0 (±0) | 1.0 (±0) | 2.0 (±0)* |
| PGA-scaffold | Fixed with fibrin glue | 2.5 (±0.7) | 2.5 (±0.7) | 3.0 (±0.7) | 2.0 (±0.0) |
| PGA-PM-scaffold | Fixed with fibrin glue | 3.5 (±0.7)* | 3.5 (±0.7)* | 4.0 (±0.7)* | 3.0 (±0.0)* |
|
|
Average per scoring item for the scaffold fixation techniques after 50 cycles (*).
|