Experimental design.

Autologous
nerve transplant
ANT
3D-chitosan core
in epineurial sheaths
CES
Composite graft
(chitosan core in PCL shell)
COM

Histological and material assessment , week 2 , week 2 , week 2
, week 13 , week 13 , week 13
Functional evaluation
 Static sciatic index, weekly
 Pinch test, weekly
 Electrophysiology
 Muscle weight ratio
Nerve morphometry
 Nerve fiber assessment
 Myelin thickness and -ratio

Summary of the experimental design and illustration of the animal/specimen number ( ) subjected to each evaluation. Varying animal numbers displayed for the evaluation of the Static Sciatic Index and the electrophysiological measurements are due to hamstrung toe contractures, signs of automutilation, and death of two animals during the course of the experiment.