Research Article

Comparison of Lyophilized Glutaraldehyde-Preserved Bovine Pericardium with Different Vascular Prostheses for Use as Vocal Cords Implants: Experimental Study

Table 2

Endoscopic changes of VC after medialization and () statistical significance of the findings.

Endoscopic findings after medialization of vocal cords with different implants
Study groups
LGPBP
()
PTFE
()
PET
()
TF
()
value

Motility of VC during all study time18666
Volume maintenance and position of VC with respect to the glottic after medialization186600.001
Kruskal-Wallis
Degree of inflammation and edema of the VC during the first postoperative week18 mild6 moderate6 moderate6 severe0.001
Kruskal-Wallis
Disappearance of inflammation2 weeks after surgery2 weeks after surgery2 weeks after surgery4 weeks after surgery
Extrusion of the implant00030.005, Kruskal-Wallis

Lyophilized glutaraldehyde-preserved bovine pericardium (LGPBP), polytetrafluoroethylene (PTFE), polyethylene terephthalate (PET), and Teflon felt (TF).