Salivary Desmoglein Enzyme-Linked Immunosorbent Assay for Diagnosis of Pemphigus Vulgaris: A Noninvasive Alternative Test to Serum Assessment

Table 5

Serum anti-Dsg 1, serum anti-Dsg3, and salivary antidesmoglein 3 ELISA main diagnostic outcomes using the manufacturer’s suggested cut-off value of 20 RU/mL.

Serum anti-Dsg 1 ELISASerum anti-Dsg 3 ELISASalivary anti-Dsg 3 ELISA

True positive628363
True negative176176178
False positive442
False negative24323
Sensitivity72.09%96.51%73.26%
Specificity97.78%97.78%98.89%
Positive predictive values0.940.950.97
Negative predictive values0.880.980.89
Test accuracy0.890.970.91
Positive likelihood ratio32.4443.3365.93
Negative likelihood ratio0.290.040.27
Diagnostic odds ratio113.671217.33243.78
Cohen’s kappa coefficient0.890.970.90