Research Article

Simultaneous Channel and Feature Selection of Fused EEG Features Based on Sparse Group Lasso

Table 3

Experimental results comparing different feature extraction methods for dataset E.

Feature extraction methodExperimental results
Number of channelsNumber of features Test error rate (%)

Power spectrum409314.85
Time-domain statistic 339116.16
AR coefficient2810217.47
Wavelet feature2543019.65
Fusion feature2350815.28