Effects of Sevoflurane and Propofol on Organ Blood Flow in Left Ventricular Assist Devices in Pigs

Table 2

Hemodynamic parameters in both groups (propofol and sevoflurane) at baseline and 30 minutes after implantation of a left ventricular assist device.

Propofol
= 5
Sevoflurane
= 5
values

HR (beats/min)
 Baseline95 ± 489 ± 90.546
 PS 30′101 ± 6101 ± 60.964
APm (mmHg)
 Baseline70 ± 365 ± 50.384
 PS 30′65 ± 874 ± 70.404
(mmHg)
 Baseline23 ± 225 ± 20.506
 PS 30′27 ± 133 ± 30.083
CVP (mmHg)
 Baseline15 ± 115 ± 10.856
 PS 30′14 ± 316 ± 20.584
CPP (mmHg)
 Baseline18 ± 118 ± 10.471
 PS 30′15 ± 0.519 ± 10.052
SVRI
 Baseline1583 ± 1991368 ± 1430.450
 PS 30′1128 ± 1731433 ± 2340.351
PVRI
 Baseline171 ± 65159 ± 320.877
 PS 30′217 ± 37339 ± 850.269
CO (L/min)
 Baseline2.4 ± 0.33 ± 0.30.185
 PS 30′2.5 ± 0.43.1 ± 0.40.347
SvO2 (%)
 Baseline77 ± 482 ± 30.429
 PS 30′82 ± 189 ± 30.150
(°C)
 Baseline35.1 ± 0.235.9 ± 0.3 0.080
 PS 30′33.9 ± 0.434.6 ± 0.40.332

Data are expressed as the mean ± standard error of the mean. HR: heart rate; APm: mean arterial blood pressure; : pulmonary artery mean pressure; CVP: central venous pressure; CPP: pulmonary capillary wedge pressure; SVRI: systemic vascular resistance index; PVRI: pulmonary vascular resistance index; CO: continuous cardiac output; SvO2: mixed venous oxygen saturation; : temperature; PS: partial support.