Research Article

An Improved Computer Vision Method for White Blood Cells Detection

Table 2

Comparative leukocyte detection performance of the BSV approach, the IO method, the Wang algorithm, the BGA detector, and the proposed DE method over the data set which contains 30 images and 426 leukocytes.

Leukocyte typeMethodLeukocytes detectedMissingFalse alarmsDRFAR

Bright leukocytes (287)BSV [3]1301578445.30%29.27%
IO [4]227607379.09%25.43%
Wang [5]231566080.49%20.90%
GAB [12]220672276.65%7.66%
DE based28161197.91%3.83%

Dark leukocytes (230)BSV [3]1051255946.65%25.65%
IO [4]183476179.56%26.52%
Wang [5]196344785.22%20.43%
GAB [12]179512377.83%10.00%
DE based2273398.70%1.30%

Overall (517)BSV [3]23528214345.45%27.66%
IO [4]41010713479.30%25.92%
Wang [5]4279010782.59%20.70%
GAB [12]3991184577.18%8.70%
DE based50891498.26%2.71%