Research Article

Evaluation of the Diagnostic Power of Thermography in Breast Cancer Using Bayesian Network Classifiers

Table 3

Accuracy, sensitivity, and specificity results for the three Bayesian network classifiers presented in Section 3.2.1.

Naïve Bayes Hill-Climber Repeated Hill-Climber

Accuracy 71.88% (±12.61) 76.10% (±7.10) 76.12% (±7.19)
Sensitivity 82% (74–91) 97% (94–100) 99% (96–100)
Specificity 37% (15–59) 0% (0-0) 0% (0-0)