Research Article
Detection of Pulmonary Nodules in CT Images Based on Fuzzy Integrated Active Contour Model and Hybrid Parametric Mixture Model
Table 5
K-fold CV results using the grid search for optimal parameters of C-SVM classifier.
| Parameters | TP | FN | TN | FP | Sensitivity | Specificity | Accuracy | AUC |
| , , and | 18 | 9 | 85 | 21 | 0.667 | 0.802 | 0.774 | 0.7529 | , , and | 13 | 7 | 72 | 8 | 0.650 | 0.9 | 0.85 | 0.7769 | , , and | 11 | 4 | 52 | 11 | 0.733 | 0.825 | 0.808 | 0.7359 | , , and | 10 | 3 | 46 | 7 | 0.769 | 0.868 | 0.848 | 0.7688 | , , and | 7 | 4 | 42 | 3 | 0.636 | 0.933 | 0.875 | 0.7769 | , , and | 7 | 2 | 36 | 3 | 0.778 | 0.923 | 0.896 | 0.8610 | , , and | 7 | 1 | 32 | 3 | 0.875 | 0.914 | 0.907 | 0.9116 | , , and | 7 | 1 | 30 | 1 | 0.875 | 0.968 | 0.949 | 0.9159 |
|
|