The iOSC3 System: Using Ontologies and SWRL Rules for Intelligent Supervision and Care of Patients with Acute Cardiac Disorders
Table 3
Example of test case. The MAP value (40.0) is lower than its lower limit (50.0). Other patient parameters have normal values. In this situation, the decision would be to decrease the vasodilator infusion rate and increase the amine infusion rate.
Parameter
Unit
Value
Lower limit
Upper limit
Vital parameters
Mean arterial pressure (MAP)
mmHg
40.0
50.0
90.0
Oxygen saturation (SpO2)
%
92.0
90.0
100.0
Central venous pressure (CVP)
mmHg
10.0
4.0
20.0
Cardiac frequency (CF)
bpm
76.0
40.0
120.0
Cardiac index (CI)
L/min/m2
2.3
Ref. value: 2.2
Temp (T)
°C
37.1
32.0
39.0
Infusion rates
Vasodilator pump
mL/h
4.0
0.0
10.0
Amine pump
mL/h
2.0
0.0
10.0
Expected recommendation
Decrease the infusion rate at the vasodilator pump and increase the infusion rate at the amine pump