Research Article
Nonrigid 3D Medical Image Registration and Fusion Based on Deformable Models
Table 1
Segmentation quality.
| Image | DSC | (mm) | (mm) | U | GC |
| t06 (P1) | 0.958 | 0.575 | 4.482 | 0.927 | 0.311 | t07 (P1) | 0.966 | 0.450 | 3.153 | 0.928 | 0.311 | t09 (P1) | 0.971 | 0.351 | 2.104 | 0.921 | 0.248 | t08 (P2) | 0.960 | 0.628 | 4.275 | 0.910 | 0.144 | t16 (P2) | 0.966 | 0.517 | 3.512 | 0.918 | 0.151 |
| Mean | 0.964 | 0.504 | 3.505 | 0.921 | 0.233 |
|
|
DSC: dice similarity coefficient. : averaged contour misalignment. : Hausdorff distance. U: intraregion uniformity. GC: gray level contrast.
|