Comparative results with previous methods for the Sliver07-test datasets.
| Method | Runtime [s] | Auto | VOE [%] | RVD [%] | ASD [mm] | RMSD [mm] | MaxD [mm] | Score |
| Peng [10] | 180 | Semi | 6.10 | −0.00 | 0.90 | 1.60 | 16.80 | 81.8 | Chen [23] | 60–180 | Semi | 4.16 | 3.53 | 0.72 | 1.26 | 16.70 | 81.5 | Peng [24] | 120–180 | Semi | 4.58 | 1.08 | 0.68 | 1.45 | 16.88 | 83.4 | Li [20] | 285 | Auto | 6.24 | 1.18 | 1.03 | 2.11 | 18.82 | 77.9 | Platero [18] | 261 | Auto | 7.60 | −0.50 | 1.30 | 2.90 | 24.70 | 70.5 | Our method | 27 | Auto | 7.87 | 1.31 | 1.29 | 2.50 | 23.56 | 71.4 |
|
|