Research Article

Permeability Prediction of Iron Tailings Including Degree of Compaction and Structure

Table 2

The measured permeability and calculated permeability of undisturbed tailings.

Numbernnsiltnclayd20 (μm)Measured permeability (cm/s)Calculated permeability (cm/s)Ratio

1-10.36410.682058.733.21 × 10−42.08 × 10−40.65
1-20.39550.759874.173.47 × 10−44.14 × 10−41.19
1-30.40760.710759.733.21 × 10−43.24 × 10−41.01
1-40.40560.761472.173.17 × 10−44.33 × 10−41.37
1-50.40510.64380.956947.362.58 × 10−42.88 × 10−41.12
1-60.39800.698459.733.28 × 10−43.00 × 10−40.92
1-70.41460.47030.915815.661.21 × 10−58.66 × 10−60.71
1-80.29900.44990.72347.913.26 × 10−53.45 × 10−51.06
1-90.32370.48220.765610.155.58 × 10−56.81 × 10−51.22
1-100.36060.50100.78629.22.29 × 10−56.13 × 10−52.68
1-110.39140.61530.872822.92.40 × 10−51.19 × 10−50.49
1-120.35660.49720.75205.712.27 × 10−52.14 × 10−50.94

Ratio = calculated permeability ÷ measured permeability.